Solar plant: site data

Solar power plant in Kovpyta, Chernihivskyi Raion, Chernihiv Oblast

Kovpyta: 1,112 kWh per kWp a year, tilt 39° 2° east of south (PVGIS). Exactly the oblast median (1,108). #156 of 479 in the rayon, #607 of 1558 in the oblast.

Chernihiv, the rayon centre, is 33 km away. 127 m above sea level. 33 km away: Chernihiv, the nearest bigger centre, 1,105 — 0.6% more here. Snow and wind from the nearest regional centre in the DBN — Чернігів, 32 km. 14.14 m between rows, pitch 17.86 m (latitude 51.4°).

Yield of 1 kWp
1,112kWh/year
Tilt
39°2° east of south
10 kW
11,119kWh/year
Row pitch
17.86m · GCR 0.27
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,720 / 410Pa

Ground frame designer

A ground frame for a solar plant: Kovpyta

The designer opens with this place’s coordinates, latitude 51.4° for the row spacing and the DBN loads of the nearest regional centre — Чернігів, 32 km: snow 1,720 Pa, wind 410 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

37Jan59Feb98Mar119Apr138May141Jun139Jul135Aug111Sep76Oct33Nov26Dec

June: 141 kWh/kWp, December: 26 — 5.4 times less.

December: 26 against 24 in the oblast, 8.3% more.

Kovpyta: plants, kWh
kWpA yearJuneDecember
55,560705130
1011,1191,410260
1516,6792,115390

Snow and wind: Чернігів

Example: a 10 kW ground frame

For the loads of Chernihiv: 11.16 kWp, 18 panels, 389 kg of steel, 12 piles, materials ≈ 52,358 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Chernihivskyi RaionChernihiv Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.