Section of the table from the Solispec engine (median zone — Cherkasy)

Aiko

Ground frame for 5 Aiko Comet 2N AIKO-A620-MAH72Mw panels (1×5)

1 row of 5 panels, 3.10 kW. The Solispec engine chose the profiles, the frame pitch and the footings for three snow and wind zones: Kherson has the lowest load of the regional centres, Cherkasy the median, Chernihiv the highest.

Power
3.10kW
Steel
140.5kg
Posts
8
Bolts
54
Materials
20,935₴
Yield
3,530kWh/year

Figures for the median zone (Cherkasy); all three zones are in the table below.

Ground frame designer

Open this frame in the builder

The builder opens with the Aiko Comet 2N AIKO-A620-MAH72Mw panel and the 1 × 5 layout; site — Cherkasy. Change the site, the tilt or the profiles and the checks and estimate are recalculated.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Three snow and wind zones

The same table designed for three regional centres: with the lowest, the median and the highest combined snow and wind load under DBN V.1.2-2:2006. For another site, open the frame in the builder.

ParameterLow loadKherson · S₀ 760 · W₀ 480Median loadCherkasy · S₀ 1,520 · W₀ 420High loadChernihiv · S₀ 1,720 · W₀ 410
PostsC-channel 80×40×2Tube 60×60×2Tube 60×60×2
RaftersC-channel 80×40×2C-channel 60×40×2C-channel 60×40×2
Purlins and bracesC-channel 41×41×2.5C-channel 60×40×2C-channel 60×40×2
Frames4 frames, pitch up to 1,780 mm4 frames, pitch up to 1,780 mm4 frames, pitch up to 1,780 mm
Posts888
Footings (bored concrete)8 pcs, Ø300 mm, depth 900 mm8 pcs, Ø300 mm, depth 1,100 mm8 pcs, Ø300 mm, depth 1,300 mm
Concrete0.56 m³0.68 m³0.81 m³
Tilt30°30°30°
Panel bottom / post top600 / 1,326 mm600 / 1,318 mm600 / 1,318 mm
Panel field size5,890 × 1,419 mm5,890 × 1,423 mm5,890 × 1,423 mm
Row spacing between tables (no shade on 21 December)5,210 mm at noon · 5,860 mm ±2 h5,780 mm at noon · 6,670 mm ±2 h6,330 mm at noon · 7,530 mm ±2 h
Steel116.6 kg140.5 kg146.3 kg
BoltsM10 — 42, M8 — 12M10 — 42, M8 — 12M10 — 42, M8 — 12
Panel clampsend 4, middle 8end 4, middle 8end 4, middle 8
Materials19,421 UAH20,935 UAH21,597 UAH
With installation and delivery28,436 UAH29,960 UAH30,622 UAH
Per 1 kW9,173 UAH/kW9,665 UAH/kW9,878 UAH/kW
Yield1,266 kWh/kW · 3,926 kWh/year1,139 kWh/kW · 3,530 kWh/year1,043 kWh/kW · 3,234 kWh/year
Strength σ/fy86%67%72%
Deflection / (L/200)76%47%50%
Rafter strength8%16%17%
Post utilisation12%7%7%
Utilisation64%46%38%
Depth vs frost depthokokok
Checks overallwith a cautionpassespasses

Checks and cautions

Member utilisation as the engine computes it. Cautions are checks that pass, but with a small margin.

  • Max. frame pitch, mmThe purlins between the frames are used above 80 % (strength or deflection): the structure passes, but the margin is small. A shorter frame pitch or a deeper purlin gives more margin.Kherson: Frame spacing 1 780 mm, 4 frames. Purlin C-channel 41×41×2.5: strength 86%, deflection 76% of L/200 (snow on panel 489 Pa).

Bill of materials

The parts of one table for the median zone (Cherkasy): mark, name, profile, cut length, quantity.

MarkPartProfileLength, mmQuantity
П1Front postTube 60×60×22,0134
П2Rear postTube 60×60×22,4434
Кр1Rafter (inclined beam)C-channel 60×40×21,4834
Пк1Frame strutC-channel 60×40×29814
Х1Longitudinal brace (cross)C-channel 60×40×21,9344
Р1Purlin (rail)C-channel 60×40×25,8902
—Bolt M10×25 set · purlins, braces, connectors——2
—Bolt M10×80 set · purlin to rafter——8
—Bolt M10×90 set · strut to post — through spacer inserts——4
—Bolt M10×130 set · post–rafter — through spacer inserts——16
—Bolt M10×140 set · strut to rafter — through spacer inserts——4
—Bolt M10×150 set · brace to post — through spacer inserts——8
—End clamp 33 mm——4
—Mid clamp (30–40 mm)——8
—Bolt M8×50 + channel nut——12
—Concrete for 8 posts, Ø300×1100——0.68 m³

Profile cutting

9 bars of 6,000 mm, 47.2 m of profile in total.

  • Tube 60×60×24 bars
  • C-channel 60×40×25 bars

Estimated cost

The engine's materials estimate for the median zone (Cherkasy).

Materials
20,935₴
With installation and delivery
29,960₴
Per 1 kW
9,665UAH/kW

The engine's estimate has 22 lines; the full list is in the builder. Prices are the typical market prices built into the Solispec engine, as of 06.10.2026; no margin, no VAT.

Yield

Yield: 1,139 kWh per 1 kW a year, ≈ 3,530 kWh a year in total (median zone, Cherkasy; tilt 30°, the optimum for the latitude is 35.3°).

A preliminary calculation; a design needs an engineer's check. Snow and wind per DBN V.1.2-2:2006 for the regional centre; profiles, footings and estimate by the Solispec engine 0.12.0.

Other layouts of this panel