1 1341 75730
Drawn to scale from the datasheet dimensions, mm

Aiko

Aiko Neostar 2P AIKO-A460-MAH54Mw

Aiko Neostar 2P AIKO-A460-MAH54Mw — solar panel: 460 W, 1,757×1,134×30 mm, 21.5 kg, Voc 41.06 V, Isc 14.25 A. On the Deye SUN-3.6K-SG03LP1-EU at −20 °C a string takes 6–11 modules. One module covers 1.99 m², that is 4.3 m² per kWp.

Power
460W
Voc
41.06V
Isc
14.25A
Weight
21.5kg

    Ground frame designer

    A ground frame for Aiko Neostar 2P AIKO-A460-MAH54Mw

    The designer opens with this panel: its size and weight are already in the profiles, posts and estimate.

    • No sign-up
    • Snow and wind check
    • Drawings and estimate

    Specifications

    ManufacturerAiko
    Power, W460
    Dimensions, mm1757×1134×30
    Weight, kg21.5
    Cells108 (54) 182 мм
    Voc, V41.06
    Isc, A14.25
    Vmp, V34.62
    Imp, A13.29
    Temp. coeff. Voc, %/°C-0.22
    Bifacialno

    Data from manufacturer datasheets; check before purchase.

    For the installer: space, weight and strings

    Module area, m²1.99
    Area per kWp, m²4.3
    Weight per kWp, kg46.7
    Module efficiency (STC), %23.1
    For 10 kWp22 modules (10.1 kWp)

    Modules per string: −20 °C and a +70 °C cell

    InverterPer stringModule Voc at −20 °C, VStrings per MPPT inputMax per inverterCheck
    Deye SUN-3.6K-SG03LP1-EU6–1145.12110 pcs · 4.6 kWpCalculator
    Growatt SPF 5000 ES5–945.1219 pcs · 4.1 kWpCalculator
    Solis S6-EH1P6K-L-PLUS4–1145.12120 pcs · 9.2 kWpCalculator

    The Solispec engine computes the window: Voc at −20 °C sets the string maximum, Vmp at a +70 °C cell sets the MPPT minimum. Check both makers’ datasheets.

    Snow and wind loads depend on the site. Calculate for your address

    Datasheet

    The specifications on this page come from this document; it opens on the maker’s site.

    The maker’s documents

    • Installation manual AIKO PV Modules Installation Manual (EN)
    • Installation manual AIKO Unpacking and Unloading Instruction for PV modules (EN)
    • Warranty AIKO N-Type ABC Module Warranty, Distributed Common Modules (WI-0BQM-M008) (EN)
    • Certificate MCS certificate (MCS 005/010/011) for AIKO single- and dual-glass modules (EN)

    Manuals, certificates and the warranty — PDFs on the maker’s site; the document’s language in brackets.

    Aiko Neostar 2P AIKO-A460-MAH54Mw datasheet + a string calculation — by e-mail

    One e-mail: the maker’s datasheet (PDF), the calculator with this model and the designer.

    With the e-mail we reserve −20 % off Pro for this address — confirm it in a separate e-mail.

    How we handle your data: privacy policy.

    Similar models from other makers

    Other Aiko models

    All Aiko models (4)

    Frequently asked questions

    How many Aiko Neostar 2P AIKO-A460-MAH54Mw modules fit in a string on the Deye SUN-3.6K-SG03LP1-EU?
    At −20 °C from 6 to 11 modules: the upper limit comes from the cold Voc and the input’s maximum voltage, the lower one from the MPPT window with a +70 °C cell.
    How much space and weight do Aiko Neostar 2P AIKO-A460-MAH54Mw modules take per kWp?
    4.3 m² and 46.7 kg per kWp (one module is 1.99 m²). A 10 kWp plant needs 22 modules.
    What is the open-circuit voltage of the Aiko Neostar 2P AIKO-A460-MAH54Mw in the cold?
    The datasheet gives a Voc of 41.06 V at STC; at −20 °C the Solispec engine gives 45.12 V per module. The string length depends on that number.