510725225
Drawn to scale from the datasheet dimensions, mm

Fronius

Fronius Symo 20.0-3-M

Fronius Symo 20.0-3-M — inverter: 20 kW, 3 phases, 2 MPPT, MPPT 200–800 V. With the Jinko Tiger Neo JKM620N-66HL4M-V at −20 °C a string holds 6–18 modules, at most 36 panels (22.3 kWp) on the whole inverter.

Power
20kW
Phases
3
MPPT trackers
2
Max DC
1,000V
  • Grid-tie

Ground frame designer

A ground-mounted plant with the Fronius Symo 20.0-3-M inverter

Design the frame — the inverter is already in the project’s electrics, and Solispec lays out the strings.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Specifications

ManufacturerFronius
TypeGrid-tie
Phases3
Power, kW20
Max DC voltage, V1,000
MPPT range, V200–800
MPPT2
Max short-circuit current per MPPT, A56
Max operating current per MPPT, A27
Max PV power, kW30
Housing W×H×D, mm510×725×225
Weight, kg39.8
Mountingwall

Data from manufacturer datasheets; check before purchase.

For the installer: which panels and how many per string

Modules per string: −20 °C and a +70 °C cell

PanelPer stringModule Voc at −20 °C, VStrings per MPPT inputMax per inverterCheck
Jinko Tiger Neo JKM620N-66HL4M-V6–1854.46136 pcs · 22.3 kWpCalculator
Astronergy ASTRO N7s CHSM48RN(DG)/F-BH-4608–2440.87148 pcs · 22.1 kWpCalculator
LONGi Hi-MO 5 LR5-72HBD-545M6–1755.57255 pcs · 30 kWpCalculator

The Solispec engine computes the window: Voc at −20 °C sets the string maximum, Vmp at a +70 °C cell sets the MPPT minimum. Check both makers’ datasheets.

Datasheet

The specifications on this page come from this document; it opens on the maker’s site.

Fronius Symo 20.0-3-M datasheet + a string calculation — by e-mail

One e-mail: the maker’s datasheet (PDF), the calculator with this model and the designer.

With the e-mail we reserve −20 % off Pro for this address — confirm it in a separate e-mail.

How we handle your data: privacy policy.

Compatible batteries

A match by both datasheets: the battery maker names the inverter's brand, the voltage class (LV/HV) matches and, for LV, the battery's nominal voltage is inside the inverter's window. Check the exact model and firmware in the maker's compatibility list.

A grid-tie inverter with no battery input.

Frequently asked questions

What are the MPPT window and inputs of the Fronius Symo 20.0-3-M?
MPPT window 200–800 V, maximum input voltage 1,000 V, 2 MPPT inputs, short-circuit current up to 56 A per input.
How many Jinko Tiger Neo JKM620N-66HL4M-V panels fit in a string on the Fronius Symo 20.0-3-M?
At −20 °C from 6 to 18 modules per string.
How many Jinko Tiger Neo JKM620N-66HL4M-V panels can be connected to the Fronius Symo 20.0-3-M?
At most 36 panels (22.3 kWp): 2 MPPT inputs × 1 string(s) per input × up to 18 modules per string, within the inverter’s maximum PV power.