Jinko · Deye

Jinko Tiger Neo JKM640N-78HL4-BDV + Deye SUN-10K-G06P3-EU-BM2: how many panels per string

From 3 to 16 Jinko Tiger Neo JKM640N-78HL4-BDV panels per string on an MPPT input of the Deye SUN-10K-G06P3-EU-BM2 inverter — in any climatic region of Ukraine. Below: the window for each region, the input currents and example plants laid out by the Solispec engine.

Panels per string
3–16pcs
Input V_max
1,100V
MPPT window
120–1,000V
Panel I_sc
13.98A
MPPT input I_sc
19.5A
Panel V_mp in heat
40.9V

Ground frame designer

A ground plant with Jinko Tiger Neo JKM640N-78HL4-BDV

The builder opens with this panel and the Deye SUN-10K-G06P3-EU-BM2 inverter: Solispec lays out the strings itself.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

String by climatic region

T_min per ДСТУ-Н Б В.1.1-27:2010, табл. 1; open-circuit voltage at T_min: K_U = 1 + α·(T_min − 25)/100 = 1.17 (α -0.25 %/K, T_min -42 °C; Annex B).

RegionT_minPanel U_oc at T_min, VMin per stringMax per stringString U_oc at max, V (≤ 1,100)
Region I-40 °C66.663161,066.5
Region II-42 °C66.943161,071.1
Region IIIA-38 °C66.373161,061.9
Region IIIB-32 °C65.513161,048.2
Region IV-20 °C63.793171,084.4
Region V-27 °C64.793161,036.7

The minimum per string keeps the string voltage in heat (panel V_mp 40.9 V) above the MPPT window (120 V).

Input currents

Panel I_sc / MPPT input I_sc, A13.98 / 19.5
Panel I_mp / MPPT input I_mp, A13.33 / 13.0
Parallel strings per MPPT1
MPPT inputs2
  • Power clippingThe panel's working current (13.33 A) is above the input's working current (13.0 A): on clear days the inverter clips part of the power.

Example plants

The Solispec engine laid out the strings for plants of several sizes with this inverter at the lowest T_min; only those that pass the checks with every panel placed are shown.

PlantPanelskW DCInvertersStringsDC/AC
≈ 5 kW85.1218 pan. × 1 — inv. 1, MPPT 10.51
≈ 10 kW1610.24116 pan. × 1 — inv. 1, MPPT 11.02
≈ 15 kW2415.36212 pan. × 1 — inv. 1, MPPT 1; 12 pan. × 1 — inv. 2, MPPT 10.77
  • current 13.3 A > 13 A — the inverter will clip (clipping)
  • DC/AC 0.51 — inverter oversized
  • U_OC MAX 1 071 В > 1000 В — звірте максимальну напругу системи панелей і апаратів (паспорт, 712.512.1.1)

A preliminary calculation; a design needs an engineer's check. Solispec engine 0.12.0.