Jinko · Deye
Jinko Tiger Neo JKM620N-66HL4M-V + Deye SUN-5K-G05P1-EU-AM2: how many panels per string
From 3 to 9 Jinko Tiger Neo JKM620N-66HL4M-V panels per string on an MPPT input of the Deye SUN-5K-G05P1-EU-AM2 inverter — in any climatic region of Ukraine. Below: the window for each region, the input currents and example plants laid out by the Solispec engine.
- Panels per string
- 3–9pcs
- Input V_max
- 550V
- MPPT window
- 70–500V
- Panel I_sc
- 16.15A
- MPPT input I_sc
- 27.0A
- Panel V_mp in heat
- 34.8V
Ground frame designer
A ground plant with Jinko Tiger Neo JKM620N-66HL4M-V
The builder opens with this panel and the Deye SUN-5K-G05P1-EU-AM2 inverter: Solispec lays out the strings itself.
- No sign-up
- Snow and wind check
- Drawings and estimate
String by climatic region
T_min per ДСТУ-Н Б В.1.1-27:2010, табл. 1; open-circuit voltage at T_min: K_U = 1 + α·(T_min − 25)/100 = 1.17 (α -0.25 %/K, T_min -42 °C; Annex B).
| Region | T_min | Panel U_oc at T_min, V | Min per string | Max per string | String U_oc at max, V (≤ 550) |
|---|---|---|---|---|---|
| Region I | -40 °C | 56.90 | 3 | 9 | 512.1 |
| Region II | -42 °C | 57.15 | 3 | 9 | 514.3 |
| Region IIIA | -38 °C | 56.66 | 3 | 9 | 509.9 |
| Region IIIB | -32 °C | 55.93 | 3 | 9 | 503.3 |
| Region IV | -20 °C | 54.46 | 3 | 10 | 544.6 |
| Region V | -27 °C | 55.31 | 3 | 9 | 497.8 |
The minimum per string keeps the string voltage in heat (panel V_mp 34.8 V) above the MPPT window (70 V).
Input currents
| Panel I_sc / MPPT input I_sc, A | 16.15 / 27.0 |
|---|---|
| Panel I_mp / MPPT input I_mp, A | 15.16 / 18.0 |
| Parallel strings per MPPT | 1 |
| MPPT inputs | 2 |
No cautions about the currents.
Example plants
The Solispec engine laid out the strings for plants of several sizes with this inverter at the lowest T_min; only those that pass the checks with every panel placed are shown.
| Plant | Panels | kW DC | Inverters | Strings | DC/AC |
|---|---|---|---|---|---|
| ≈ 5 kW | 9 | 5.58 | 1 | 9 pan. × 1 — inv. 1, MPPT 1 | 1.12 |
| ≈ 10 kW | 18 | 11.16 | 2 | 9 pan. × 1 — inv. 1, MPPT 1; 9 pan. × 1 — inv. 2, MPPT 1 | 1.12 |
| ≈ 15 kW | 25 | 15.50 | 3 | 5 pan. × 1 — inv. 1, MPPT 1; 5 pan. × 1 — inv. 1, MPPT 2; 5 pan. × 1 — inv. 2, MPPT 1; 5 pan. × 1 — inv. 2, MPPT 2; 5 pan. × 1 — inv. 3, MPPT 1 | 1.03 |
- DC/AC 0.62 — inverter oversized
A preliminary calculation; a design needs an engineer's check. Solispec engine 0.12.0.