Astronergy · Deye

Astronergy ASTRO N7 Pro CHSM66RN(DG)/F-BQ-660 + Deye SUN-20K-SG01HP3-EU-AM2: how many panels per string

From 5 to 17 Astronergy ASTRO N7 Pro CHSM66RN(DG)/F-BQ-660 panels per string on an MPPT input of the Deye SUN-20K-SG01HP3-EU-AM2 inverter — in any climatic region of Ukraine. Below: the window for each region, the input currents and example plants laid out by the Solispec engine.

Panels per string
5–17pcs
Input V_max
1,000V
MPPT window
150–850V
Panel I_sc
16.72A
MPPT input I_sc
39.0A
Panel V_mp in heat
35.3V

Ground frame designer

A ground plant with Astronergy ASTRO N7 Pro CHSM66RN(DG)/F-BQ-660

The builder opens with this panel and the Deye SUN-20K-SG01HP3-EU-AM2 inverter: Solispec lays out the strings itself.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

String by climatic region

T_min per ДСТУ-Н Б В.1.1-27:2010, табл. 1; open-circuit voltage at T_min: K_U = 1 + α·(T_min − 25)/100 = 1.15 (α -0.23 %/K, T_min -42 °C; Annex B).

RegionT_minPanel U_oc at T_min, VMin per stringMax per stringString U_oc at max, V (≤ 1,000)
Region I-40 °C56.65517963.0
Region II-42 °C56.87517966.9
Region IIIA-38 °C56.42517959.2
Region IIIB-32 °C55.74517947.6
Region IV-20 °C54.38518978.9
Region V-27 °C55.17518993.1

The minimum per string keeps the string voltage in heat (panel V_mp 35.3 V) above the MPPT window (150 V).

Input currents

Panel I_sc / MPPT input I_sc, A16.72 / 39.0
Panel I_mp / MPPT input I_mp, A15.94 / 26.0
Parallel strings per MPPT1
MPPT inputs2

No cautions about the currents.

Example plants

The Solispec engine laid out the strings for plants of several sizes with this inverter at the lowest T_min; only those that pass the checks with every panel placed are shown.

PlantPanelskW DCInvertersStringsDC/AC
≈ 5 kW85.2818 pan. × 1 — inv. 1, MPPT 10.26
≈ 10 kW1610.56116 pan. × 1 — inv. 1, MPPT 10.53
≈ 15 kW2315.18112 pan. × 1 — inv. 1, MPPT 1; 11 pan. × 1 — inv. 1, MPPT 20.76
  • DC/AC 0.26 — inverter oversized
  • DC/AC 0.53 — inverter oversized

A preliminary calculation; a design needs an engineer's check. Solispec engine 0.12.0.

Next

Other inverters for Astronergy ASTRO N7 Pro CHSM66RN(DG)/F-BQ-660

Other panels for Deye SUN-20K-SG01HP3-EU-AM2