Astronergy · Solis

Astronergy ASTRO N7 CHSM66RN(DG)/F-BH-640 + Solis S6-GR1P3K: how many panels per string

From 2 to 9 Astronergy ASTRO N7 CHSM66RN(DG)/F-BH-640 panels per string on an MPPT input of the Solis S6-GR1P3K inverter — in any climatic region of Ukraine. Below: the window for each region, the input currents and example plants laid out by the Solispec engine.

Panels per string
2–9pcs
Input V_max
550V
MPPT window
50–450V
Panel I_sc
16.42A
MPPT input I_sc
22.0A
Panel V_mp in heat
35.8V

Ground frame designer

A ground plant with Astronergy ASTRO N7 CHSM66RN(DG)/F-BH-640

The builder opens with this panel and the Solis S6-GR1P3K inverter: Solispec lays out the strings itself.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

String by climatic region

T_min per ДСТУ-Н Б В.1.1-27:2010, табл. 1; open-circuit voltage at T_min: K_U = 1 + α·(T_min − 25)/100 = 1.17 (α -0.25 %/K, T_min -42 °C; Annex B).

RegionT_minPanel U_oc at T_min, VMin per stringMax per stringString U_oc at max, V (≤ 550)
Region I-40 °C57.6329518.6
Region II-42 °C57.8729520.9
Region IIIA-38 °C57.3829516.4
Region IIIB-32 °C56.6329509.7
Region IV-20 °C55.1529496.3
Region V-27 °C56.0129504.1

The minimum per string keeps the string voltage in heat (panel V_mp 35.8 V) above the MPPT window (50 V).

Input currents

Panel I_sc / MPPT input I_sc, A16.42 / 22.0
Panel I_mp / MPPT input I_mp, A15.24 / 14.0
Parallel strings per MPPT1
MPPT inputs2
  • Power clippingThe panel's working current (15.24 A) is above the input's working current (14.0 A): on clear days the inverter clips part of the power.

Example plants

The Solispec engine laid out the strings for plants of several sizes with this inverter at the lowest T_min; only those that pass the checks with every panel placed are shown.

PlantPanelskW DCInvertersStringsDC/AC
≈ 5 kW74.4827 pan. × 1 — inv. 1, MPPT 10.75
≈ 10 kW1710.8833 pan. × 1 — inv. 1, MPPT 1; 3 pan. × 1 — inv. 1, MPPT 2; 3 pan. × 1 — inv. 2, MPPT 1; 3 pan. × 1 — inv. 2, MPPT 2; 3 pan. × 1 — inv. 3, MPPT 1; 2 pan. × 1 — inv. 3, MPPT 21.21
≈ 15 kW2516.0055 pan. × 1 — inv. 1, MPPT 1; 5 pan. × 1 — inv. 2, MPPT 1; 5 pan. × 1 — inv. 3, MPPT 1; 5 pan. × 1 — inv. 4, MPPT 1; 5 pan. × 1 — inv. 5, MPPT 11.07
  • current 15.2 A > 14 A — the inverter will clip (clipping)
  • DC/AC 1.49 — will clip peaks
  • nothing connected

A preliminary calculation; a design needs an engineer's check. Solispec engine 0.12.0.

Next

Other inverters for Astronergy ASTRO N7 CHSM66RN(DG)/F-BH-640

Other panels for Solis S6-GR1P3K