PV structure: Krakow, Gdansk, Zakopane, snow and wind

The same ground-mount PV structure in Krakow, Gdansk and Zakopane. National-annex snow and wind values change the member utilisation, truss spacing and ballast weight.

Por Solispec editorial6 min de lectura

Este texto aún no está traducido — se muestra el original.

The same ground-mount PV table, five portrait panels at 34 degrees on a 41 x 41 x 3 mm C profile, uses its most loaded member to 74 % in Krakow, 96 % in Gdansk and 118 % in Zakopane, which means it fails there. The structure is identical; only the snow and wind values of the Polish national annex change. In Zakopane the table has to be shortened to three panels or the profile changed.

Below: the assumptions, where the snow and wind come from for each site, the results of the Solispec engine and what they mean for a designer. The figures come from the same engine that stands behind the ground truss calculator and the snow and wind calculator.

The structure

The example uses the default settings of the ground truss calculator:

  • panels 2350 x 1100 mm, 5 in portrait on one truss, tilt 34 degrees;
  • perforated C profile 41 x 41, wall 3 mm;
  • supports: precast concrete cubes of 150 kg under each leg, the number of cubes follows from the check;
  • terrain category II, a row of six trusses.

The calculator's default wall of 2 mm still passes in Krakow (rafter K1 used to 99 %) but fails in Gdansk (129 %), so 3 mm is taken for all three sites.

Where snow and wind come from at the three sites

Characteristic loads are the values of the national annex to PN-EN 1991-1-3 (snow) and PN-EN 1991-1-4 (wind). Load combinations follow EN 1990 with a factor of 1.5 on variable actions.

SiteAltitudeSnow zones_kWind zoneq_b
Krakow219 m31.2 kN/m² (1200 Pa)10.30 kN/m² (300 Pa)
Gdansk8 m31.2 kN/m² (1200 Pa)20.42 kN/m² (420 Pa)
Zakopane855 m5 (Tatra)2.93 kN/m² (2930 Pa)30.49 kN/m² (490 Pa)

The engine receives s_k and q_b in pascals, rounded up to 10 Pa (unchanged for Krakow and Gdansk: 300 and 420 Pa). Krakow and Gdansk share a snow zone; wind separates them, since Gdansk is in zone 2 (the Baltic coastal belt).

Zakopane: the values are entered by hand

Zakopane is not in the tool's city list. The calculator proposes the values of the nearest main city from its list, here a centre about 65 km away, with snow of 1200 Pa and wind of 300 Pa. That is more than twice too little snow. For Zakopane the user therefore enters the values by hand in the snow and wind fields:

  • Snow. Zakopane lies in zone 5 (Tatra). The formula of table NB.1 is s_k = 0.93 · exp(0.00134 · A), not less than 2.0 kN/m². We use A = 855 m (the altitude of the weather station in Zakopane's climate data; the town itself spans 800 to 1100 m). This gives s_k = 2.925 kN/m², 2930 Pa in the engine. For a plot higher or lower, recompute from its own altitude.
  • Wind. We take zone 3 (southern Carpathians), because the zone description in our data ties it to the Sudetes and the southern Carpathians, and the nearest listed city also sits in zone 3. This is an assumption from that description, not a point reading of the annex map. For zone 3 above 300 m, q_b = 0.30 · [1 + 0.0006 (A - 300)]² · (20000 - A) / (20000 + A), which is 0.489 kN/m² at 855 m. If the map placed the plot in zone 1 the value would be higher (0.533 kN/m²). The designer confirms the zone on the plot.

Engine results

Design snow is s_k with the factor 1.5 at ground level, and wind pressure is taken at a height of 2 m in terrain category II (the snow and wind calculator's outputs). The snow shape coefficient and the pressure coefficients for the tilted plane are applied inside the truss check.

KrakowGdanskZakopane
Design snow, Pa180018004395
Design wind, Pa6418971046
Most loaded member (rafter K1)74 %96 %118 %
Resultpassespasses, small marginfails
Truss spacing (5 panels)1040 mm1040 mm1040 mm
Cubes of 150 kg under one support345
Weight per support (sliding)393 kg584 kg713 kg

What changes

Krakow to Gdansk: wind. Snow is the same, but the wind pressure rises from 300 to 420 Pa. The utilisation of rafter K1 goes from 74 to 96 %, and a support needs 584 kg instead of 393 kg, a fourth cube instead of a third. In Gdansk the margin is already small: the thinner 2 mm wall gives 129 % and fails.

Krakow to Zakopane: snow and wind together. Snow rises from 1800 to 4395 Pa and wind to 1046 Pa. Rafter K1 with a 3 mm wall reaches 118 %. A support needs 713 kg, five cubes. Snow loads mainly the profile, while the support weight is set by wind, which is also the strongest of the three sites in Zakopane.

How the Zakopane table is saved

The engine offers two changes. First: three panels per truss instead of five. Truss spacing then falls to 630 mm, rafter K1 to 80 % and the support to 390 kg, three cubes. Second: a tube profile instead of the perforated C. The choice between them belongs to the designer, but the direction is clear: the more snow, the shorter the table or the stronger the profile.

Conclusions

  1. A structure is not universal. The same geometry needs a different profile and ballast by zone.
  2. Between Krakow and Gdansk only wind differs, and it raises the support weight and the utilisation. In Zakopane snow joins in and it decides that the profile fails.
  3. Places outside the list need snow and wind entered by hand. A value proposed from the nearest city can understate mountain snow by more than half (here 1200 Pa instead of 2930 Pa).
  4. Profile and ballast also depend on tilt, the number of panels per truss and the kind of support (piles instead of cubes).

A comparison of the engine with a hand calculation is on the calculation check page. The full set with drawings and cut lists comes from the designer; a sample report is on the samples page.

The calculation is preliminary. Loads are the Polish national annex values and combinations follow EN 1990. A qualified engineer must check it before installation.

FAQ

How is the snow load in Zakopane found?

For zone 5 (Tatra) with s_k = 0.93 · exp(0.00134 · A), not less than 2.0 kN/m². For 855 m this gives 2.93 kN/m². Use the altitude of your own plot.

Why does the calculator not know Zakopane?

The list holds larger cities. For a place outside it the calculator proposes the nearest city's values, which can be too low in the mountains, so snow and wind are entered by hand.

Will the same structure do for all of Poland?

Not always. It passes with room in Krakow, with a small margin in Gdansk, and fails in Zakopane unless the profile or the number of panels per truss changes.

EstructurasNormas

Novedades y consejos de diseño

Qué hay de nuevo en Solispec, cambios en la normativa y consejos prácticos para diseñar instalaciones solares.

Qué te interesa

Cómo tratamos tus datos: política de privacidad.

Diseñador de estructuras en suelo

Diseña la estructura en suelo de tu planta solar

Solispec elige los perfiles y postes, comprueba la estructura frente a la nieve y el viento y la presupuesta hasta el último tornillo.

  • Sin registro
  • Comprobación de nieve y viento
  • Planos y presupuesto