Solar plant: site data
Solar power plant in Selezivka, Korostenskyi Raion, Zhytomyr Oblast
Selezivka: 1,052 kWh per kWp a year, tilt 39° 5° east of south (PVGIS). 4.7% below the oblast median (1,104). #556 of 560 in the rayon, #1696 of 1700 in the oblast.
Korosten, the rayon centre, is 75 km away. 151 m above sea level. 75 km away: Korosten, the nearest bigger centre, 1,105 — 4.8% less here. Snow and wind from the nearest regional centre in the DBN — Житомир, 148 km. 14.33 m between rows, pitch 18.05 m (latitude 51.5°).
- Yield of 1 kWp
- 1,052kWh/year
- Tilt
- 39°5° east of south
- 10 kW
- 10,524kWh/year
- Row pitch
- 18.05m · GCR 0.27
- T_min
- -40 °Cregion I, north-western
- Snow S₀ / wind W₀
- 1,460 / 460Pa
Ground frame designer
A ground frame for a solar plant: Selezivka
The designer opens with this place’s coordinates, latitude 51.5° for the row spacing and the DBN loads of the nearest regional centre — Житомир, 148 km: snow 1,460 Pa, wind 460 Pa.
- No sign-up
- Snow and wind check
- Drawings and estimate
Yield by month
June: 134 kWh/kWp, December: 27 — 5.0 times less.
October: 75 against 81 in the oblast, 7.4% less.
| kWp | A year | June | December |
|---|---|---|---|
| 5 | 5,262 | 670 | 135 |
| 10 | 10,524 | 1,340 | 270 |
| 15 | 15,786 | 2,010 | 405 |
Example: a 10 kW ground frame
For the loads of Zhytomyr: 11.16 kWp, 18 panels, 350 kg of steel, 12 piles, materials ≈ 52,606 UAH.
How these numbers are computed
Nearby
- Syrnytsia12 km1,052 kWh/kWp
- Pobychi13 km1,051 kWh/kWp
- Chervonosilka14 km1,055 kWh/kWp
- Deleta14 km1,060 kWh/kWp
- Duby15 km1,058 kWh/kWp
- Kovanka16 km1,050 kWh/kWp
All places: Korostenskyi RaionZhytomyr Oblast: rayons and towns
Free calculators
Sources
- PVGIS © European Union, 2001–2026 — yield, tilt and azimuth, data as of 2026-10-10
- GeoNames (CC BY 4.0) — coordinates, elevation and divisions (changed)
- DBN V.1.2-2:2006, DSTU-N B V.1.1-27:2010
- How these numbers are computed
Preliminary calculation: a design needs an engineer’s check.