Solar plant: site data

Solar power plant in Hruzlyvets, Zhytomyrskyi Raion, Zhytomyr Oblast

Hruzlyvets: 1,112 kWh per kWp a year, tilt 38° 3° east of south (PVGIS). 0.7% above the oblast median (1,104). #291 of 686 in the rayon, #391 of 1700 in the oblast.

Zhytomyr, the rayon centre, is 45 km away. 224 m above sea level. 40 km away: Zvyahel, the nearest bigger centre, 1,101 — 1.0% more here. Snow and wind from the nearest regional centre in the DBN — Житомир, 44 km. 12.75 m between rows, pitch 16.52 m (latitude 50.4°).

Yield of 1 kWp
1,112kWh/year
Tilt
38°3° east of south
10 kW
11,121kWh/year
Row pitch
16.52m · GCR 0.29
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,460 / 460Pa

Ground frame designer

A ground frame for a solar plant: Hruzlyvets

The designer opens with this place’s coordinates, latitude 50.4° for the row spacing and the DBN loads of the nearest regional centre — Житомир, 44 km: snow 1,460 Pa, wind 460 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

35Jan58Feb93Mar118Apr134May140Jun139Jul136Aug112Sep82Oct36Nov29Dec

June: 140 kWh/kWp, December: 29 — 4.8 times less.

December: 29 against 27 in the oblast, 7.4% more.

Hruzlyvets: plants, kWh
kWpA yearJuneDecember
55,561700145
1011,1211,400290
1516,6822,100435

Snow and wind: Житомир

Example: a 10 kW ground frame

For the loads of Zhytomyr: 11.16 kWp, 18 panels, 350 kg of steel, 12 piles, materials ≈ 52,606 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Zhytomyrskyi RaionZhytomyr Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.