Solar plant: site data

Solar power plant in Klitytsk, Kamin-Kashyrskyi Raion, Volyn Oblast

Klitytsk: 1,044 kWh per kWp a year, tilt 39° 5° east of south (PVGIS). 3.7% below the oblast median (1,084). #165 of 167 in the rayon, #1118 of 1120 in the oblast.

Kamin-Kashyrskyi, the rayon centre, is 8 km away. 167 m above sea level. 8 km away: Kamin-Kashyrskyi, the nearest bigger centre, 1,058 — 1.3% less here. Snow and wind from the nearest regional centre in the DBN — Луцьк, 93 km. 14.36 m between rows, pitch 18.08 m (latitude 51.6°).

Yield of 1 kWp
1,044kWh/year
Tilt
39°5° east of south
10 kW
10,438kWh/year
Row pitch
18.08m · GCR 0.26
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,240 / 480Pa

Ground frame designer

A ground frame for a solar plant: Klitytsk

The designer opens with this place’s coordinates, latitude 51.6° for the row spacing and the DBN loads of the nearest regional centre — Луцьк, 93 km: snow 1,240 Pa, wind 480 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

34Jan50Feb92Mar113Apr124May130Jun130Jul130Aug103Sep75Oct35Nov27Dec

June: 130 kWh/kWp, December: 27 — 4.8 times less.

October: 75 against 80 in the oblast, 6.3% less.

Klitytsk: plants, kWh
kWpA yearJuneDecember
55,219650135
1010,4381,300270
1515,6571,950405

Snow and wind: Луцьк

Example: a 10 kW ground frame

For the loads of Lutsk: 11.16 kWp, 18 panels, 387 kg of steel, 14 piles, materials ≈ 51,425 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Kamin-Kashyrskyi RaionVolyn Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.