Solar plant: site data

Solar power plant in Chykalivka, Kremenchutskyi Raion, Poltava Oblast

Chykalivka: 1,163 kWh per kWp a year, tilt 36° 2° east of south (PVGIS). 1.9% above the oblast median (1,142). #134 of 329 in the rayon, #186 of 1856 in the oblast.

Kremenchuk, the rayon centre, is 17 km away. 66 m above sea level. 14 km away: Onufriyivka, the nearest bigger centre, 1,173 — 0.8% less here. Snow and wind from the nearest regional centre in the DBN — Полтава, 97 km. 10.94 m between rows, pitch 14.81 m (latitude 49.0°).

Yield of 1 kWp
1,163kWh/year
Tilt
36°2° east of south
10 kW
11,633kWh/year
Row pitch
14.81m · GCR 0.32
T_min
-42 °Cregion II, south-eastern
Snow S₀ / wind W₀
1,450 / 470Pa

Ground frame designer

A ground frame for a solar plant: Chykalivka

The designer opens with this place’s coordinates, latitude 49.0° for the row spacing and the DBN loads of the nearest regional centre — Полтава, 97 km: snow 1,450 Pa, wind 470 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

36Jan55Feb95Mar119Apr141May145Jun149Jul148Aug120Sep88Oct41Nov27Dec

July: 149 kWh/kWp, December: 27 — 5.5 times less.

December: 27 against 25 in the oblast, 8.0% more.

Chykalivka: plants, kWh
kWpA yearJulyDecember
55,817745135
1011,6331,490270
1517,4502,235405

Snow and wind: Полтава

Example: a 10 kW ground frame

For the loads of Poltava: 11.16 kWp, 18 panels, 363 kg of steel, 12 piles, materials ≈ 54,473 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Kremenchutskyi RaionPoltava Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.