Solar plant: site data

Solar power plant in Ustymivka, Bilotserkivskyi Raion, Kyiv Oblast

Ustymivka: 1,113 kWh per kWp a year, tilt 37° 3° east of south (PVGIS). 0.8% below the oblast median (1,122). #258 of 260 in the rayon, #831 of 1071 in the oblast.

Bila Tserkva, the rayon centre, is 20 km away. 186 m above sea level. 14 km away: Fastiv, the nearest bigger centre, 1,119 — 0.6% less here. Snow and wind from the nearest regional centre in the DBN — Київ, 65 km. 12.05 m between rows, pitch 15.87 m (latitude 50.0°).

Yield of 1 kWp
1,113kWh/year
Tilt
37°3° east of south
10 kW
11,126kWh/year
Row pitch
15.87m · GCR 0.30
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,550 / 370Pa

Ground frame designer

A ground frame for a solar plant: Ustymivka

The designer opens with this place’s coordinates, latitude 50.0° for the row spacing and the DBN loads of the nearest regional centre — Київ, 65 km: snow 1,550 Pa, wind 370 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

30Jan51Feb90Mar118Apr137May144Jun146Jul139Aug113Sep83Oct35Nov26Dec

July: 146 kWh/kWp, December: 26 — 5.6 times less.

January: 30 against 34 in the oblast, 11.8% less.

Ustymivka: plants, kWh
kWpA yearJulyDecember
55,563730130
1011,1261,460260
1516,6892,190390

Snow and wind: Київ

Example: a 10 kW ground frame

For the loads of Kyiv: 11.16 kWp, 18 panels, 350 kg of steel, 12 piles, materials ≈ 49,237 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Bilotserkivskyi RaionKyiv Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.