Solar plant: site data

Solar power plant in Bila Tserkva, Bilotserkivskyi Raion, Kyiv Oblast

Bila Tserkva: 1,122 kWh per kWp a year, tilt 37° 3° east of south (PVGIS). Exactly the oblast median (1,122). #175 of 260 in the rayon, #526 of 1071 in the oblast.

Bila Tserkva is the rayon centre. 163 m above sea level. 79 km away: Kyiv, the nearest bigger centre, 1,114 — 0.7% more here. Snow and wind from the nearest regional centre in the DBN — Київ, 78 km. 11.90 m between rows, pitch 15.72 m (latitude 49.8°).

Yield of 1 kWp
1,122kWh/year
Tilt
37°3° east of south
10 kW
11,223kWh/year
Row pitch
15.72m · GCR 0.30
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,550 / 370Pa

Ground frame designer

A ground frame for a solar plant: Bila Tserkva

The designer opens with this place’s coordinates, latitude 49.8° for the row spacing and the DBN loads of the nearest regional centre — Київ, 78 km: snow 1,550 Pa, wind 370 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

33Jan54Feb92Mar118Apr137May142Jun144Jul139Aug113Sep84Oct37Nov29Dec

July: 144 kWh/kWp, December: 29 — 5.0 times less.

December: 29 against 27 in the oblast, 7.4% more.

Bila Tserkva: plants, kWh
kWpA yearJulyDecember
55,612720145
1011,2231,440290
1516,8352,160435

Snow and wind: Київ

Example: a 10 kW ground frame

For the loads of Kyiv: 11.16 kWp, 18 panels, 350 kg of steel, 12 piles, materials ≈ 49,237 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Bilotserkivskyi RaionKyiv Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.