Solar plant: site data

Solar power plant in Zbrizh, Kamianets-Podilskyi Raion, Khmelnytskyi Oblast

Zbrizh: 1,118 kWh per kWp a year, tilt 37° 1° east of south (PVGIS). 1.7% above the oblast median (1,100). #182 of 226 in the rayon, #254 of 1109 in the oblast.

Kamyanets-Podilskyi, the rayon centre, is 38 km away. 225 m above sea level. 32 km away: Chortkiv, the nearest bigger centre, 1,126 — 0.6% less here. Snow and wind from the nearest regional centre in the DBN — Чернівці, 72 km. 11.14 m between rows, pitch 14.96 m (latitude 48.9°).

Yield of 1 kWp
1,118kWh/year
Tilt
37°1° east of south
10 kW
11,184kWh/year
Row pitch
14.96m · GCR 0.32
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,320 / 500Pa

Ground frame designer

A ground frame for a solar plant: Zbrizh

The designer opens with this place’s coordinates, latitude 48.9° for the row spacing and the DBN loads of the nearest regional centre — Чернівці, 72 km: snow 1,320 Pa, wind 500 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

37Jan55Feb94Mar117Apr132May135Jun141Jul137Aug113Sep85Oct39Nov32Dec

July: 141 kWh/kWp, December: 32 — 4.4 times less.

January: 37 against 32 in the oblast, 15.6% more.

Zbrizh: plants, kWh
kWpA yearJulyDecember
55,592705160
1011,1841,410320
1516,7762,115480

Snow and wind: Чернівці

Example: a 10 kW ground frame

For the loads of Chernivtsi: 11.16 kWp, 18 panels, 412 kg of steel, 16 piles, materials ≈ 54,638 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Kamianets-Podilskyi RaionKhmelnytskyi Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.