Solar plant: site data

Solar power plant in Studenitsa, Kamianets-Podilskyi Raion, Khmelnytskyi Oblast

Studenitsa: 1,140 kWh per kWp a year, tilt 36° 2° east of south (PVGIS). 3.6% above the oblast median (1,100). #50 of 226 in the rayon, #50 of 1109 in the oblast.

Kamyanets-Podilskyi, the rayon centre, is 27 km away. 127 m above sea level. 14 km away: Kelmentsi, the nearest bigger centre, 1,148 — 0.7% less here. Snow and wind from the nearest regional centre in the DBN — Чернівці, 79 km. 10.63 m between rows, pitch 14.50 m (latitude 48.6°).

Yield of 1 kWp
1,140kWh/year
Tilt
36°2° east of south
10 kW
11,399kWh/year
Row pitch
14.50m · GCR 0.33
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,320 / 500Pa

Ground frame designer

A ground frame for a solar plant: Studenitsa

The designer opens with this place’s coordinates, latitude 48.6° for the row spacing and the DBN loads of the nearest regional centre — Чернівці, 79 km: snow 1,320 Pa, wind 500 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

37Jan55Feb97Mar119Apr136May136Jun142Jul140Aug115Sep87Oct42Nov34Dec

July: 142 kWh/kWp, December: 34 — 4.2 times less.

December: 34 against 29 in the oblast, 17.2% more.

Studenitsa: plants, kWh
kWpA yearJulyDecember
55,700710170
1011,3991,420340
1517,0992,130510

Snow and wind: Чернівці

Example: a 10 kW ground frame

For the loads of Chernivtsi: 11.16 kWp, 18 panels, 412 kg of steel, 16 piles, materials ≈ 54,638 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Kamianets-Podilskyi RaionKhmelnytskyi Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.