Solar plant: site data

Solar power plant in Stavchany, Kamianets-Podilskyi Raion, Khmelnytskyi Oblast

Stavchany: 1,147 kWh per kWp a year, tilt 37° 2° east of south (PVGIS). 4.3% above the oblast median (1,100). #13 of 226 in the rayon, #13 of 1109 in the oblast.

Kamyanets-Podilskyi, the rayon centre, is 55 km away. 260 m above sea level. 34 km away: Vinkivtsi, the nearest bigger centre, 1,127 — 1.8% more here. Snow and wind from the nearest regional centre in the DBN — Хмельницький, 80 km. 11.00 m between rows, pitch 14.82 m (latitude 48.7°).

Yield of 1 kWp
1,147kWh/year
Tilt
37°2° east of south
10 kW
11,473kWh/year
Row pitch
14.82m · GCR 0.32
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,340 / 500Pa

Ground frame designer

A ground frame for a solar plant: Stavchany

The designer opens with this place’s coordinates, latitude 48.7° for the row spacing and the DBN loads of the nearest regional centre — Хмельницький, 80 km: snow 1,340 Pa, wind 500 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

39Jan55Feb96Mar120Apr137May139Jun143Jul141Aug115Sep88Oct42Nov34Dec

July: 143 kWh/kWp, December: 34 — 4.2 times less.

January: 39 against 32 in the oblast, 21.9% more.

Stavchany: plants, kWh
kWpA yearJulyDecember
55,737715170
1011,4731,430340
1517,2102,145510

Snow and wind: Хмельницький

Example: a 10 kW ground frame

For the loads of Khmelnytskyi: 11.16 kWp, 18 panels, 415 kg of steel, 16 piles, materials ≈ 55,054 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Kamianets-Podilskyi RaionKhmelnytskyi Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.