Solar plant: site data

Solar power plant in Shepetivka, Shepetivskyi Raion, Khmelnytskyi Oblast

Shepetivka: 1,085 kWh per kWp a year, tilt 37° 2° east of south (PVGIS). 1.4% below the oblast median (1,100). #238 of 307 in the rayon, #951 of 1109 in the oblast.

Shepetivka is the rayon centre. 254 m above sea level. 60 km away: Zvyahel, the nearest bigger centre, 1,101 — 1.5% less here. Snow and wind from the nearest regional centre in the DBN — Рівне, 76 km. 12.26 m between rows, pitch 16.08 m (latitude 50.2°).

Yield of 1 kWp
1,085kWh/year
Tilt
37°2° east of south
10 kW
10,851kWh/year
Row pitch
16.08m · GCR 0.30
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,320 / 520Pa

Ground frame designer

A ground frame for a solar plant: Shepetivka

The designer opens with this place’s coordinates, latitude 50.2° for the row spacing and the DBN loads of the nearest regional centre — Рівне, 76 km: snow 1,320 Pa, wind 520 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

32Jan51Feb88Mar117Apr132May137Jun137Jul136Aug110Sep82Oct36Nov27Dec

June: 137 kWh/kWp, December: 27 — 5.1 times less.

December: 27 against 29 in the oblast, 6.9% less.

Shepetivka: plants, kWh
kWpA yearJuneDecember
55,426685135
1010,8511,370270
1516,2762,055405

Snow and wind: Рівне

Example: a 10 kW ground frame

For the loads of Rivne: 11.16 kWp, 18 panels, 415 kg of steel, 16 piles, materials ≈ 55,054 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Shepetivskyi RaionKhmelnytskyi Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.