Solar plant: site data

Solar power plant in Pyshky, Khmelnytskyi Raion, Khmelnytskyi Oblast

Pyshky: 1,092 kWh per kWp a year, tilt 36° 2° east of south (PVGIS). 0.8% below the oblast median (1,100). #379 of 576 in the rayon, #780 of 1109 in the oblast.

Khmelnytskyi, the rayon centre, is 64 km away. 284 m above sea level. 20 km away: Stara Synyava, the nearest bigger centre, 1,109 — 1.5% less here. Snow and wind from the nearest regional centre in the DBN — Хмельницький, 63 km. 11.60 m between rows, pitch 15.47 m (latitude 49.8°).

Yield of 1 kWp
1,092kWh/year
Tilt
36°2° east of south
10 kW
10,916kWh/year
Row pitch
15.47m · GCR 0.31
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,340 / 500Pa

Ground frame designer

A ground frame for a solar plant: Pyshky

The designer opens with this place’s coordinates, latitude 49.8° for the row spacing and the DBN loads of the nearest regional centre — Хмельницький, 63 km: snow 1,340 Pa, wind 500 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

29Jan47Feb83Mar118Apr135May140Jun142Jul138Aug112Sep84Oct37Nov28Dec

July: 142 kWh/kWp, December: 28 — 5.1 times less.

January: 29 against 32 in the oblast, 9.4% less.

Pyshky: plants, kWh
kWpA yearJulyDecember
55,458710140
1010,9161,420280
1516,3742,130420

Snow and wind: Хмельницький

Example: a 10 kW ground frame

For the loads of Khmelnytskyi: 11.16 kWp, 18 panels, 415 kg of steel, 16 piles, materials ≈ 55,054 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Khmelnytskyi RaionKhmelnytskyi Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.