Solar plant: site data

Solar power plant in Chereshenka, Khmelnytskyi Raion, Khmelnytskyi Oblast

Chereshenka: 1,112 kWh per kWp a year, tilt 36° 2° west of south (PVGIS). 1.1% above the oblast median (1,100). #130 of 576 in the rayon, #345 of 1109 in the oblast.

Khmelnytskyi, the rayon centre, is 39 km away. 275 m above sea level. 6 km away: Derazhnya, the nearest bigger centre, 1,118 — 0.5% less here. Snow and wind from the nearest regional centre in the DBN — Хмельницький, 38 km. 11.20 m between rows, pitch 15.07 m (latitude 49.3°).

Yield of 1 kWp
1,112kWh/year
Tilt
36°2° west of south
10 kW
11,119kWh/year
Row pitch
15.07m · GCR 0.32
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,340 / 500Pa

Ground frame designer

A ground frame for a solar plant: Chereshenka

The designer opens with this place’s coordinates, latitude 49.3° for the row spacing and the DBN loads of the nearest regional centre — Хмельницький, 38 km: snow 1,340 Pa, wind 500 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

33Jan52Feb89Mar119Apr136May139Jun141Jul139Aug113Sep84Oct37Nov30Dec

July: 141 kWh/kWp, December: 30 — 4.7 times less.

December: 30 against 29 in the oblast, 3.4% more.

Chereshenka: plants, kWh
kWpA yearJulyDecember
55,560705150
1011,1191,410300
1516,6792,115450

Snow and wind: Хмельницький

Example: a 10 kW ground frame

For the loads of Khmelnytskyi: 11.16 kWp, 18 panels, 415 kg of steel, 16 piles, materials ≈ 55,054 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Khmelnytskyi RaionKhmelnytskyi Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.