Solar plant: site data

Solar power plant in Chepelivka, Khmelnytskyi Raion, Khmelnytskyi Oblast

Chepelivka: 1,087 kWh per kWp a year, tilt 36° 1° east of south (PVGIS). 1.2% below the oblast median (1,100). #462 of 576 in the rayon, #905 of 1109 in the oblast.

Khmelnytskyi, the rayon centre, is 27 km away. 301 m above sea level. 7 km away: Krasyliv, the nearest bigger centre, the same 1,086. Snow and wind from the nearest regional centre in the DBN — Хмельницький, 27 km. 11.49 m between rows, pitch 15.36 m (latitude 49.7°).

Yield of 1 kWp
1,087kWh/year
Tilt
36°1° east of south
10 kW
10,867kWh/year
Row pitch
15.36m · GCR 0.31
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,340 / 500Pa

Ground frame designer

A ground frame for a solar plant: Chepelivka

The designer opens with this place’s coordinates, latitude 49.7° for the row spacing and the DBN loads of the nearest regional centre — Хмельницький, 27 km: snow 1,340 Pa, wind 500 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

30Jan47Feb84Mar117Apr134May137Jun139Jul137Aug113Sep84Oct37Nov28Dec

July: 139 kWh/kWp, December: 28 — 5.0 times less.

February: 47 against 51 in the oblast, 7.8% less.

Chepelivka: plants, kWh
kWpA yearJulyDecember
55,434695140
1010,8671,390280
1516,3012,085420

Snow and wind: Хмельницький

Example: a 10 kW ground frame

For the loads of Khmelnytskyi: 11.16 kWp, 18 panels, 415 kg of steel, 16 piles, materials ≈ 55,054 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Khmelnytskyi RaionKhmelnytskyi Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.