Solar plant: site data
Solar power plant in Zoriane, Berestynskyi Raion, Kharkiv Oblast
Zoriane: 1,149 kWh per kWp a year, tilt 37° 2° east of south (PVGIS). 0.6% above the oblast median (1,142). #109 of 208 in the rayon, #423 of 1769 in the oblast.
Berestyn, the rayon centre, is 8 km away. 143 m above sea level. 8 km away: Berestyn, the nearest bigger centre, 1,158 — 0.8% less here. Snow and wind from the nearest regional centre in the DBN — Полтава, 65 km. 11.59 m between rows, pitch 15.41 m (latitude 49.4°).
- Yield of 1 kWp
- 1,149kWh/year
- Tilt
- 37°2° east of south
- 10 kW
- 11,492kWh/year
- Row pitch
- 15.41m · GCR 0.31
- T_min
- -42 °Cregion II, south-eastern
- Snow S₀ / wind W₀
- 1,450 / 470Pa
Ground frame designer
A ground frame for a solar plant: Zoriane
The designer opens with this place’s coordinates, latitude 49.4° for the row spacing and the DBN loads of the nearest regional centre — Полтава, 65 km: snow 1,450 Pa, wind 470 Pa.
- No sign-up
- Snow and wind check
- Drawings and estimate
Yield by month
July: 149 kWh/kWp, December: 25 — 6.0 times less.
January: 37 against 39 in the oblast, 5.1% less.
| kWp | A year | July | December |
|---|---|---|---|
| 5 | 5,746 | 745 | 125 |
| 10 | 11,492 | 1,490 | 250 |
| 15 | 17,238 | 2,235 | 375 |
Example: a 10 kW ground frame
For the loads of Poltava: 11.16 kWp, 18 panels, 363 kg of steel, 12 piles, materials ≈ 54,473 UAH.
How these numbers are computed
Nearby
- Vyshneve2 km1,155 kWh/kWp
- Novoselivka4 km1,155 kWh/kWp
- Pokrovske5 km1,159 kWh/kWp
- Tyshenkivka6 km1,144 kWh/kWp
- Shevchenka6 km1,155 kWh/kWp
- Pishchanka6 km1,158 kWh/kWp
All places: Berestynskyi RaionKharkiv Oblast: rayons and towns
Free calculators
Sources
- PVGIS © European Union, 2001–2026 — yield, tilt and azimuth, data as of 2026-10-10
- GeoNames (CC BY 4.0) — coordinates, elevation and divisions (changed)
- DBN V.1.2-2:2006, DSTU-N B V.1.1-27:2010
- How these numbers are computed
Preliminary calculation: a design needs an engineer’s check.