Solar plant: site data
Solar power plant in Kazankivka, Kryvorizkyi Raion, Dnipropetrovsk Oblast
Kazankivka: 1,195 kWh per kWp a year, tilt 36° 3° east of south (PVGIS). 1.5% above the oblast median (1,177). #55 of 272 in the rayon, #156 of 1501 in the oblast.
Kryvyy Rih, the rayon centre, is 33 km away. 98 m above sea level. 23 km away: Kazanka, the nearest bigger centre, 1,179 — 1.4% more here. Snow and wind from the nearest regional centre in the DBN — Кропивницький, 109 km. 10.00 m between rows, pitch 13.87 m (latitude 47.7°).
- Yield of 1 kWp
- 1,195kWh/year
- Tilt
- 36°3° east of south
- 10 kW
- 11,949kWh/year
- Row pitch
- 13.87m · GCR 0.34
- T_min
- -42 °Cregion II, south-eastern
- Snow S₀ / wind W₀
- 1,230 / 410Pa
Ground frame designer
A ground frame for a solar plant: Kazankivka
The designer opens with this place’s coordinates, latitude 47.7° for the row spacing and the DBN loads of the nearest regional centre — Кропивницький, 109 km: snow 1,230 Pa, wind 410 Pa.
- No sign-up
- Snow and wind check
- Drawings and estimate
Yield by month
July: 151 kWh/kWp, December: 31 — 4.9 times less.
February: 60 against 54 in the oblast, 11.1% more.
| kWp | A year | July | December |
|---|---|---|---|
| 5 | 5,975 | 755 | 155 |
| 10 | 11,949 | 1,510 | 310 |
| 15 | 17,924 | 2,265 | 465 |
Example: a 10 kW ground frame
For the loads of Kropyvnytskyi: 11.16 kWp, 18 panels, 382 kg of steel, 14 piles, materials ≈ 49,026 UAH.
How these numbers are computed
Nearby
- Novomalynivka3 km1,195 kWh/kWp
- Zelenyi Stav3 km1,196 kWh/kWp
- Tsvitkove3 km1,199 kWh/kWp
- Yavdotivka4 km1,193 kWh/kWp
- Karpivka5 km1,202 kWh/kWp
- Myrne5 km1,191 kWh/kWp
All places: Kryvorizkyi RaionDnipropetrovsk Oblast: rayons and towns
Free calculators
Sources
- PVGIS © European Union, 2001–2026 — yield, tilt and azimuth, data as of 2026-10-10
- GeoNames (CC BY 4.0) — coordinates, elevation and divisions (changed)
- DBN V.1.2-2:2006, DSTU-N B V.1.1-27:2010
- How these numbers are computed
Preliminary calculation: a design needs an engineer’s check.