Solar plant: site data

Solar power plant in Chervona Nyva, Pavlohradskyi Raion, Dnipropetrovsk Oblast

Chervona Nyva: 1,169 kWh per kWp a year, tilt 36° 1° east of south (PVGIS). 0.7% below the oblast median (1,177). #35 of 89 in the rayon, #1205 of 1501 in the oblast.

Pavlohrad, the rayon centre, is 12 km away. 63 m above sea level. 12 km away: Pavlohrad, the nearest bigger centre, the same 1,172. Snow and wind from the nearest regional centre in the DBN — Дніпро, 52 km. 10.64 m between rows, pitch 14.51 m (latitude 48.6°).

Yield of 1 kWp
1,169kWh/year
Tilt
36°1° east of south
10 kW
11,685kWh/year
Row pitch
14.51m · GCR 0.33
T_min
-42 °Cregion II, south-eastern
Snow S₀ / wind W₀
1,340 / 470Pa

Ground frame designer

A ground frame for a solar plant: Chervona Nyva

The designer opens with this place’s coordinates, latitude 48.6° for the row spacing and the DBN loads of the nearest regional centre — Дніпро, 52 km: snow 1,340 Pa, wind 470 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

33Jan55Feb93Mar117Apr140May144Jun150Jul150Aug122Sep90Oct46Nov28Dec

July: 150 kWh/kWp, December: 28 — 5.4 times less.

January: 33 against 35 in the oblast, 5.7% less.

Chervona Nyva: plants, kWh
kWpA yearJulyDecember
55,843750140
1011,6851,500280
1517,5282,250420

Snow and wind: Дніпро

Example: a 10 kW ground frame

For the loads of Dnipro: 11.16 kWp, 18 panels, 346 kg of steel, 12 piles, materials ≈ 51,820 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Pavlohradskyi RaionDnipropetrovsk Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.