Solar plant: site data
Solar power plant in Behma, Synelnykivskyi Raion, Dnipropetrovsk Oblast
Behma: 1,177 kWh per kWp a year, tilt 36° 2° east of south (PVGIS). Exactly the oblast median (1,177). #140 of 370 in the rayon, #760 of 1501 in the oblast.
Synelnykove, the rayon centre, is 25 km away. 103 m above sea level. 18 km away: Vilnyansk, the nearest bigger centre, 1,191 — 1.2% less here. Snow and wind from the nearest regional centre in the DBN — Запоріжжя, 37 km. 10.29 m between rows, pitch 14.16 m (latitude 48.1°).
- Yield of 1 kWp
- 1,177kWh/year
- Tilt
- 36°2° east of south
- 10 kW
- 11,769kWh/year
- Row pitch
- 14.16m · GCR 0.34
- T_min
- -42 °Cregion II, south-eastern
- Snow S₀ / wind W₀
- 1,110 / 460Pa
Ground frame designer
A ground frame for a solar plant: Behma
The designer opens with this place’s coordinates, latitude 48.1° for the row spacing and the DBN loads of the nearest regional centre — Запоріжжя, 37 km: snow 1,110 Pa, wind 460 Pa.
- No sign-up
- Snow and wind check
- Drawings and estimate
Yield by month
July: 152 kWh/kWp, December: 27 — 5.6 times less.
February: 52 against 54 in the oblast, 3.7% less.
| kWp | A year | July | December |
|---|---|---|---|
| 5 | 5,885 | 760 | 135 |
| 10 | 11,769 | 1,520 | 270 |
| 15 | 17,654 | 2,280 | 405 |
Example: a 10 kW ground frame
For the loads of Zaporizhzhia: 11.16 kWp, 18 panels, 382 kg of steel, 14 piles, materials ≈ 50,687 UAH.
How these numbers are computed
Nearby
- Ahrafenivka2 km1,177 kWh/kWp
- Pershozvanivka4 km1,180 kWh/kWp
- Yakymivske4 km1,182 kWh/kWp
- Yakymivka5 km1,187 kWh/kWp
- Slavhorod5 km1,179 kWh/kWp
- Turhenievka6 km1,178 kWh/kWp
All places: Synelnykivskyi RaionDnipropetrovsk Oblast: rayons and towns
Free calculators
Sources
- PVGIS © European Union, 2001–2026 — yield, tilt and azimuth, data as of 2026-10-10
- GeoNames (CC BY 4.0) — coordinates, elevation and divisions (changed)
- DBN V.1.2-2:2006, DSTU-N B V.1.1-27:2010
- How these numbers are computed
Preliminary calculation: a design needs an engineer’s check.