Section of the table from the Solispec engine (Kyiv)

Ground plant · Kyiv

A 3 kW ground-mounted solar plant in Kyiv: structure, materials, cost

6 Ulica UL-620M-132DDGN (dual glass bifacial) panels (3.72 kW) on 1 table of 2 × 3. Snow and wind per the DBN for Kyiv: S₀ 1,550 Pa, W₀ 370 Pa.

Power
3.72kW
Steel
169.3kg
Posts
6
Bolts
54
Materials
21,533₴
Yield
4,050kWh/year

Ground frame designer

Design the 3 kW plant in the builder

Opens the 2 × 3 table with the Ulica UL-620M-132DDGN (dual glass bifacial) panel and the loads for Kyiv.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Panel

Ulica UL-620M-132DDGN (dual glass bifacial): 620 W, 2,382 × 1,134 mm, portrait.

The table's structure

Layout1 table, each 2 × 3 = 6 panels
Loads (DBN V.1.2-2:2006)snow S₀ 1,550 Pa, wind W₀ 370 Pa, frost depth 1.1 m
PostsTube 60×60×2
RaftersC-channel 60×40×2
Purlins and bracesC-channel 60×40×2
Frames3 frames, pitch up to 1,560 mm
Posts6
Footings (bored concrete)6 pcs, Ø300 mm, depth 1,200 mm
Concrete0.56 m³
Tilt30°
Panel bottom / post top600 / 2,287 mm
Panel field size3,582 × 3,102 mm
Row spacing between tables (no shade on 21 December)12,460 mm at noon · 14,590 mm ±2 h
Steel169.3 kg
BoltsM10 — 38, M8 — 16
Panel clampsend 8, middle 8
Materials21,533 UAH
With installation and delivery32,199 UAH
Per 1 kW8,656 UAH/kW
Yield1,089 kWh/kW · 4,050 kWh/year

Checks and cautions

CheckValueStatus
Strength σ/fy67%passes
Deflection / (L/200)54%passes
Rafter strength97%with a caution
Post utilisation19%passes
Utilisation77%passes
Depth vs frost depthokpasses
  • Rafter profileThe rafter is used above 80 %, or the frame's posts stand far apart: the structure passes, but the margin is small.Rafter C-channel 60×40×2: span between posts 2 276, cantilever 824 mm → strength 97%.

Bill of materials

MarkPartProfileLength, mmQuantity
П1Front postTube 60×60×22,3743
П2Rear postTube 60×60×23,5123
Кр1Rafter (inclined beam)C-channel 60×40×23,9243
Пк1Frame strutC-channel 60×40×21,8183
Х1Longitudinal brace (cross)C-channel 60×40×22,2754
Р1Purlin (rail)C-channel 60×40×23,5824
—Bolt M10×25 set · purlins, braces, connectors——2
—Bolt M10×80 set · purlin to rafter——12
—Bolt M10×90 set · strut to post — through spacer inserts——3
—Bolt M10×130 set · post–rafter — through spacer inserts——12
—Bolt M10×140 set · strut to rafter — through spacer inserts——3
—Bolt M10×150 set · brace to post — through spacer inserts——4
—Bolt M10×150 set · post, insert and two overlapping braces — one hole——2
—End clamp 30 mm——8
—Mid clamp (30–40 mm)——8
—Bolt M8×50 + channel nut——16
—Concrete for 6 posts, Ø300×1200——0.56 m³

Profile cutting

10 bars of 6,000 mm, 58.3 m of profile in total.

  • Tube 60×60×23 bars
  • C-channel 60×40×27 bars

Estimated cost

Materials
21,533₴
With installation and delivery
32,199₴
Per 1 kW
8,656UAH/kW

The engine's estimate has 23 lines; the full list is in the builder. Prices are the typical market prices built into the Solispec engine, as of 06.10.2026; no margin, no VAT.

Yield

Yield: 1,089 kWh per 1 kW a year, ≈ 4,050 kWh a year in total for Kyiv (tilt 30°, the optimum for the latitude is 35.7°).

A preliminary calculation; a design needs an engineer's check. Snow and wind per DBN V.1.2-2:2006 for the regional centre; profiles, footings and estimate by the Solispec engine 0.12.0.

Other sizes in Kyiv

3 kW in other regional centres

Next