Section of the table from the Solispec engine (Zhytomyr)

Ground plant · Zhytomyr

A 20 kW ground-mounted solar plant in Zhytomyr: structure, materials, cost

34 Ulica UL-620M-132DDGN (dual glass bifacial) panels (21.08 kW) on 1 table of 2 × 17. Snow and wind per the DBN for Zhytomyr: S₀ 1,460 Pa, W₀ 460 Pa.

Power
21.08kW
Steel
623.7kg
Posts
22
Bolts
240
Materials
87,836₴
Yield
23,141kWh/year

Ground frame designer

Design the 20 kW plant in the builder

Opens the 2 × 17 table with the Ulica UL-620M-132DDGN (dual glass bifacial) panel and the loads for Zhytomyr.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Panel

Ulica UL-620M-132DDGN (dual glass bifacial): 620 W, 2,382 × 1,134 mm, portrait.

The table's structure

Layout1 table, each 2 × 17 = 34 panels
Loads (DBN V.1.2-2:2006)snow S₀ 1,460 Pa, wind W₀ 460 Pa, frost depth 1.1 m
PostsTube 60×60×2
RaftersC-channel 80×40×2
Purlins and bracesC-channel 60×40×2
Frames11 frames, pitch up to 1,920 mm
Posts22
Footings (bored concrete)22 pcs, Ø350 mm, depth 1,200 mm
Concrete2.79 m³
Tilt30°
Panel bottom / post top600 / 2,278 mm
Panel field size19,738 × 3,107 mm
Row spacing between tables (no shade on 21 December)12,350 mm at noon · 14,420 mm ±2 h
Steel623.7 kg
BoltsM10 — 168, M8 — 72
Panel clampsend 8, middle 64
Materials87,836 UAH
With installation and delivery141,468 UAH
Per 1 kW6,711 UAH/kW
Yield1,098 kWh/kW · 23,141 kWh/year

Checks and cautions

CheckValueStatus
Strength σ/fy83%with a caution
Deflection / (L/200)63%passes
Rafter strength84%with a caution
Post utilisation24%passes
Utilisation98%with a caution
Depth vs frost depthokpasses
  • Max. frame pitch, mmThe purlins between the frames are used above 80 % (strength or deflection): the structure passes, but the margin is small. A shorter frame pitch or a deeper purlin gives more margin.Frame spacing 1 920 mm, 11 frames. Purlin C-channel 60×40×2: strength 83%, deflection 63% of L/200 (snow on panel 939 Pa).
  • Rafter profileThe rafter is used above 80 %, or the frame's posts stand far apart: the structure passes, but the margin is small.Rafter C-channel 80×40×2: span between posts 2 276, cantilever 824 mm → strength 84%.
  • Embedment, mmThe footing resists wind uplift at above 80 % utilisation, or it is shallower than the frost depth. The soil resistance in the calculation is an estimate — check the soil on site.Foundation Ø350 × 1 200: 0.115 m³ of concrete per post. Wind uplift on the front post ≈ 12.2 kN (with γ=1.5) vs ≈ 12.4 kN (concrete weight + soil friction, estimate) → 98%.

Bill of materials

MarkPartProfileLength, mmQuantity
П1Front postTube 60×60×22,36511
П2Rear postTube 60×60×23,50311
Кр1Rafter (inclined beam)C-channel 80×40×23,92411
Пк1Frame strutC-channel 60×40×21,81111
Х1Longitudinal brace (cross)C-channel 60×40×22,5354
Р1Purlin (rail)C-channel 60×40×26,0002
Р2Purlin (rail)C-channel 60×40×26,0002
Р3Purlin (rail)C-channel 60×40×26,0002
Р4Purlin (rail)C-channel 60×40×26,0002
Р5Purlin (rail)C-channel 60×40×26,0002
Р6Purlin (rail)C-channel 60×40×26,0002
Р7Purlin (rail)C-channel 60×40×21,7382
Р8Purlin (rail)C-channel 60×40×21,7382
—Bolt M10×25 set · purlins, braces, connectors——50
—Bolt M10×90 set · strut to post — through spacer inserts——11
—Bolt M10×100 set · purlin to rafter——44
—Bolt M10×130 set · post–rafter — through spacer inserts——44
—Bolt M10×140 set · strut to rafter — through spacer inserts——11
—Bolt M10×150 set · brace to post — through spacer inserts——8
—End clamp 30 mm——8
—Mid clamp (30–40 mm)——64
—Bolt M8×50 + channel nut——72
—Concrete for 22 posts, Ø350×1200——2.79 m³

Profile cutting

41 bars of 6,000 mm, 216.7 m of profile in total.

  • Tube 60×60×211 bars
  • C-channel 80×40×211 bars
  • C-channel 60×40×219 bars

Estimated cost

Materials
87,836₴
With installation and delivery
141,468₴
Per 1 kW
6,711UAH/kW

The engine's estimate has 24 lines; the full list is in the builder. Prices are the typical market prices built into the Solispec engine, as of 06.10.2026; no margin, no VAT.

Yield

Yield: 1,098 kWh per 1 kW a year, ≈ 23,141 kWh a year in total for Zhytomyr (tilt 30°, the optimum for the latitude is 35.6°).

A preliminary calculation; a design needs an engineer's check. Snow and wind per DBN V.1.2-2:2006 for the regional centre; profiles, footings and estimate by the Solispec engine 0.12.0.