REC · Growatt

REC Alpha Pure-RX REC470AA Pure-RX (HJT) + Growatt MIN 3000TL-X: how many panels per string

From 2 to 6 REC Alpha Pure-RX REC470AA Pure-RX (HJT) panels per string on an MPPT input of the Growatt MIN 3000TL-X inverter — in any climatic region of Ukraine. Below: the window for each region, the input currents and example plants laid out by the Solispec engine.

Panels per string
2–6pcs
Input V_max
500V
MPPT window
80–500V
Panel I_sc
8.95A
MPPT input I_sc
16.9A
Panel V_mp in heat
47.2V

Ground frame designer

A ground plant with REC Alpha Pure-RX REC470AA Pure-RX (HJT)

The builder opens with this panel and the Growatt MIN 3000TL-X inverter: Solispec lays out the strings itself.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

String by climatic region

T_min per ДСТУ-Н Б В.1.1-27:2010, табл. 1; open-circuit voltage at T_min: K_U = 1 + α·(T_min − 25)/100 = 1.16 (α -0.24 %/K, T_min -42 °C; Annex B).

RegionT_minPanel U_oc at T_min, VMin per stringMax per stringString U_oc at max, V (≤ 500)
Region I-40 °C75.9526455.7
Region II-42 °C76.2626457.6
Region IIIA-38 °C75.6326453.8
Region IIIB-32 °C74.6926448.1
Region IV-20 °C72.8026436.8
Region V-27 °C73.9026443.4

The minimum per string keeps the string voltage in heat (panel V_mp 47.2 V) above the MPPT window (80 V).

Input currents

Panel I_sc / MPPT input I_sc, A8.95 / 16.9
Panel I_mp / MPPT input I_mp, A8.49 / 13.5
Parallel strings per MPPT1
MPPT inputs2

No cautions about the currents.

Example plants

The Solispec engine laid out the strings for plants of several sizes with this inverter at the lowest T_min; only those that pass the checks with every panel placed are shown.

PlantPanelskW DCInvertersStringsDC/AC
≈ 5 kW115.1723 pan. × 1 — inv. 1, MPPT 1; 3 pan. × 1 — inv. 1, MPPT 2; 3 pan. × 1 — inv. 2, MPPT 1; 2 pan. × 1 — inv. 2, MPPT 20.86
≈ 10 kW2210.3434 pan. × 1 — inv. 1, MPPT 1; 4 pan. × 1 — inv. 1, MPPT 2; 4 pan. × 1 — inv. 2, MPPT 1; 4 pan. × 1 — inv. 2, MPPT 2; 4 pan. × 1 — inv. 3, MPPT 1; 2 pan. × 1 — inv. 3, MPPT 21.15
≈ 15 kW3215.0454 pan. × 1 — inv. 1, MPPT 1; 4 pan. × 1 — inv. 1, MPPT 2; 4 pan. × 1 — inv. 2, MPPT 1; 4 pan. × 1 — inv. 2, MPPT 2; 4 pan. × 1 — inv. 3, MPPT 1; 4 pan. × 1 — inv. 3, MPPT 2; 4 pan. × 1 — inv. 4, MPPT 1; 4 pan. × 1 — inv. 5, MPPT 11.00
  • DC/AC 0.63 — inverter oversized

A preliminary calculation; a design needs an engineer's check. Solispec engine 0.12.0.

Next

Other inverters for REC Alpha Pure-RX REC470AA Pure-RX (HJT)