REC · Growatt
REC Alpha Pure 2 REC420AA Pure 2 (HJT) + Growatt SPF 6000 ES Plus: how many panels per string
From 4 to 8 REC Alpha Pure 2 REC420AA Pure 2 (HJT) panels per string on an MPPT input of the Growatt SPF 6000 ES Plus inverter — in any climatic region of Ukraine. Below: the window for each region, the input currents and example plants laid out by the Solispec engine.
- Panels per string
- 4–8pcs
- Input V_max
- 500V
- MPPT window
- 120–450V
- Panel I_sc
- 10.83A
- MPPT input I_sc
- 16.0A
- Panel V_mp in heat
- 35.1V
Ground frame designer
A ground plant with REC Alpha Pure 2 REC420AA Pure 2 (HJT)
The builder opens with this panel and the Growatt SPF 6000 ES Plus inverter: Solispec lays out the strings itself.
- No sign-up
- Snow and wind check
- Drawings and estimate
String by climatic region
T_min per ДСТУ-Н Б В.1.1-27:2010, табл. 1; open-circuit voltage at T_min: K_U = 1 + α·(T_min − 25)/100 = 1.16 (α -0.24 %/K, T_min -42 °C; Annex B).
| Region | T_min | Panel U_oc at T_min, V | Min per string | Max per string | String U_oc at max, V (≤ 500) |
|---|---|---|---|---|---|
| Region I | -40 °C | 56.76 | 4 | 8 | 454.1 |
| Region II | -42 °C | 57.00 | 4 | 8 | 456.0 |
| Region IIIA | -38 °C | 56.52 | 4 | 8 | 452.2 |
| Region IIIB | -32 °C | 55.82 | 4 | 8 | 446.5 |
| Region IV | -20 °C | 54.40 | 4 | 9 | 489.6 |
| Region V | -27 °C | 55.23 | 4 | 9 | 497.1 |
The minimum per string keeps the string voltage in heat (panel V_mp 35.1 V) above the MPPT window (120 V).
Input currents
| Panel I_sc / MPPT input I_sc, A | 10.83 / 16.0 |
|---|---|
| Panel I_mp / MPPT input I_mp, A | 10.20 / 16.0 |
| Parallel strings per MPPT | 1 |
| MPPT inputs | 2 |
No cautions about the currents.
Example plants
The Solispec engine laid out the strings for plants of several sizes with this inverter at the lowest T_min; only those that pass the checks with every panel placed are shown.
| Plant | Panels | kW DC | Inverters | Strings | DC/AC |
|---|---|---|---|---|---|
| ≈ 5 kW | 12 | 5.04 | 1 | 6 pan. × 1 — inv. 1, MPPT 1; 6 pan. × 1 — inv. 1, MPPT 2 | 0.84 |
| ≈ 10 kW | 24 | 10.08 | 2 | 8 pan. × 1 — inv. 1, MPPT 1; 8 pan. × 1 — inv. 1, MPPT 2; 8 pan. × 1 — inv. 2, MPPT 1 | 0.84 |
| ≈ 15 kW | 36 | 15.12 | 3 | 6 pan. × 1 — inv. 1, MPPT 1; 6 pan. × 1 — inv. 1, MPPT 2; 6 pan. × 1 — inv. 2, MPPT 1; 6 pan. × 1 — inv. 2, MPPT 2; 6 pan. × 1 — inv. 3, MPPT 1; 6 pan. × 1 — inv. 3, MPPT 2 | 0.84 |
- DC/AC 0.56 — inverter oversized
A preliminary calculation; a design needs an engineer's check. Solispec engine 0.12.0.