SunPower/Maxeon · Solis

Maxeon 6 SPR-MAX6-440 (IBC) + Solis S5-GR3P5K: how many panels per string

From 5 to 19 Maxeon 6 SPR-MAX6-440 (IBC) panels per string on an MPPT input of the Solis S5-GR3P5K inverter — in any climatic region of Ukraine. Below: the window for each region, the input currents and example plants laid out by the Solispec engine.

Panels per string
5–19pcs
Input V_max
1,100V
MPPT window
160–1,000V
Panel I_sc
11.58A
MPPT input I_sc
20.0A
Panel V_mp in heat
34.5V

Ground frame designer

A ground plant with Maxeon 6 SPR-MAX6-440 (IBC)

The builder opens with this panel and the Solis S5-GR3P5K inverter: Solispec lays out the strings itself.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

String by climatic region

T_min per ДСТУ-Н Б В.1.1-27:2010, табл. 1; open-circuit voltage at T_min: K_U = 1 + α·(T_min − 25)/100 = 1.16 (α -0.239 %/K, T_min -42 °C; Annex B).

RegionT_minPanel U_oc at T_min, VMin per stringMax per stringString U_oc at max, V (≤ 1,100)
Region I-40 °C55.695191,058.1
Region II-42 °C55.925191,062.5
Region IIIA-38 °C55.465191,053.7
Region IIIB-32 °C54.775201,095.3
Region IV-20 °C53.385201,067.7
Region V-27 °C54.195201,083.8

The minimum per string keeps the string voltage in heat (panel V_mp 34.5 V) above the MPPT window (160 V).

Input currents

Panel I_sc / MPPT input I_sc, A11.58 / 20.0
Panel I_mp / MPPT input I_mp, A10.87 / 16.0
Parallel strings per MPPT1
MPPT inputs2

No cautions about the currents.

Example plants

The Solispec engine laid out the strings for plants of several sizes with this inverter at the lowest T_min; only those that pass the checks with every panel placed are shown.

PlantPanelskW DCInvertersStringsDC/AC
≈ 5 kW125.28112 pan. × 1 — inv. 1, MPPT 11.06
≈ 10 kW2310.1226 pan. × 1 — inv. 1, MPPT 1; 6 pan. × 1 — inv. 1, MPPT 2; 6 pan. × 1 — inv. 2, MPPT 1; 5 pan. × 1 — inv. 2, MPPT 21.01
≈ 15 kW3515.4037 pan. × 1 — inv. 1, MPPT 1; 7 pan. × 1 — inv. 1, MPPT 2; 7 pan. × 1 — inv. 2, MPPT 1; 7 pan. × 1 — inv. 2, MPPT 2; 7 pan. × 1 — inv. 3, MPPT 11.03
  • DC/AC 0.62 — inverter oversized

A preliminary calculation; a design needs an engineer's check. Solispec engine 0.12.0.