LONGi Hi-MO X10 LR7-72HVH-650M + Solis S6-GR1P3K: how many panels per string
From 2 to 8 LONGi Hi-MO X10 LR7-72HVH-650M panels per string on an MPPT input of the Solis S6-GR1P3K inverter — in any climatic region of Ukraine. Below: the window for each region, the input currents and example plants laid out by the Solispec engine.
- Panels per string
- 2–8pcs
- Input V_max
- 550V
- MPPT window
- 50–450V
- Panel I_sc
- 15.29A
- MPPT input I_sc
- 22.0A
- Panel V_mp in heat
- 37.9V
Ground frame designer
A ground plant with LONGi Hi-MO X10 LR7-72HVH-650M
The builder opens with this panel and the Solis S6-GR1P3K inverter: Solispec lays out the strings itself.
- No sign-up
- Snow and wind check
- Drawings and estimate
String by climatic region
T_min per ДСТУ-Н Б В.1.1-27:2010, табл. 1; open-circuit voltage at T_min: K_U = 1 + α·(T_min − 25)/100 = 1.13 (α -0.2 %/K, T_min -42 °C; Annex B).
| Region | T_min | Panel U_oc at T_min, V | Min per string | Max per string | String U_oc at max, V (≤ 550) |
|---|---|---|---|---|---|
| Region I | -40 °C | 60.91 | 2 | 9 | 548.2 |
| Region II | -42 °C | 61.12 | 2 | 8 | 489.0 |
| Region IIIA | -38 °C | 60.69 | 2 | 9 | 546.2 |
| Region IIIB | -32 °C | 60.04 | 2 | 9 | 540.4 |
| Region IV | -20 °C | 58.75 | 2 | 9 | 528.8 |
| Region V | -27 °C | 59.51 | 2 | 9 | 535.6 |
The minimum per string keeps the string voltage in heat (panel V_mp 37.9 V) above the MPPT window (50 V).
Input currents
| Panel I_sc / MPPT input I_sc, A | 15.29 / 22.0 |
|---|---|
| Panel I_mp / MPPT input I_mp, A | 14.59 / 14.0 |
| Parallel strings per MPPT | 1 |
| MPPT inputs | 2 |
- Power clippingThe panel's working current (14.59 A) is above the input's working current (14.0 A): on clear days the inverter clips part of the power.
Example plants
The Solispec engine laid out the strings for plants of several sizes with this inverter at the lowest T_min; only those that pass the checks with every panel placed are shown.
| Plant | Panels | kW DC | Inverters | Strings | DC/AC |
|---|---|---|---|---|---|
| ≈ 5 kW | 9 | 5.85 | 2 | 3 pan. × 1 — inv. 1, MPPT 1; 3 pan. × 1 — inv. 1, MPPT 2; 3 pan. × 1 — inv. 2, MPPT 1 | 0.98 |
| ≈ 10 kW | 17 | 11.05 | 3 | 3 pan. × 1 — inv. 1, MPPT 1; 3 pan. × 1 — inv. 1, MPPT 2; 3 pan. × 1 — inv. 2, MPPT 1; 3 pan. × 1 — inv. 2, MPPT 2; 3 pan. × 1 — inv. 3, MPPT 1; 2 pan. × 1 — inv. 3, MPPT 2 | 1.23 |
| ≈ 15 kW | 25 | 16.25 | 5 | 5 pan. × 1 — inv. 1, MPPT 1; 5 pan. × 1 — inv. 2, MPPT 1; 5 pan. × 1 — inv. 3, MPPT 1; 5 pan. × 1 — inv. 4, MPPT 1; 5 pan. × 1 — inv. 5, MPPT 1 | 1.08 |
- current 14.6 A > 14 A — the inverter will clip (clipping)
- DC/AC 0.65 — inverter oversized
A preliminary calculation; a design needs an engineer's check. Solispec engine 0.12.0.