LONGi · Deye

LONGi Hi-MO X10 LR7-54HVH-485M + Deye SUN-5K-SG04LP1-EU: how many panels per string

From 6 to 10 LONGi Hi-MO X10 LR7-54HVH-485M panels per string on an MPPT input of the Deye SUN-5K-SG04LP1-EU inverter — in any climatic region of Ukraine. Below: the window for each region, the input currents and example plants laid out by the Solispec engine.

Panels per string
6–10pcs
Input V_max
500V
MPPT window
150–425V
Panel I_sc
15.23A
MPPT input I_sc
27.0A
Panel V_mp in heat
28.4V

Ground frame designer

A ground plant with LONGi Hi-MO X10 LR7-54HVH-485M

The builder opens with this panel and the Deye SUN-5K-SG04LP1-EU inverter: Solispec lays out the strings itself.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

String by climatic region

T_min per ДСТУ-Н Б В.1.1-27:2010, табл. 1; open-circuit voltage at T_min: K_U = 1 + α·(T_min − 25)/100 = 1.13 (α -0.2 %/K, T_min -42 °C; Annex B).

RegionT_minPanel U_oc at T_min, VMin per stringMax per stringString U_oc at max, V (≤ 500)
Region I-40 °C45.65610456.5
Region II-42 °C45.81610458.1
Region IIIA-38 °C45.49610454.9
Region IIIB-32 °C45.01611495.1
Region IV-20 °C44.04611484.4
Region V-27 °C44.60611490.6

The minimum per string keeps the string voltage in heat (panel V_mp 28.4 V) above the MPPT window (150 V).

Input currents

Panel I_sc / MPPT input I_sc, A15.23 / 27.0
Panel I_mp / MPPT input I_mp, A14.53 / 18.0
Parallel strings per MPPT1
MPPT inputs2

No cautions about the currents.

Example plants

The Solispec engine laid out the strings for plants of several sizes with this inverter at the lowest T_min; only those that pass the checks with every panel placed are shown.

PlantPanelskW DCInvertersStringsDC/AC
≈ 5 kW125.8216 pan. × 1 — inv. 1, MPPT 1; 6 pan. × 1 — inv. 1, MPPT 21.16
≈ 10 kW2110.1927 pan. × 1 — inv. 1, MPPT 1; 7 pan. × 1 — inv. 1, MPPT 2; 7 pan. × 1 — inv. 2, MPPT 11.02
≈ 15 kW3014.55310 pan. × 1 — inv. 1, MPPT 1; 10 pan. × 1 — inv. 2, MPPT 1; 10 pan. × 1 — inv. 3, MPPT 10.97
  • DC/AC 1.36 — will clip peaks
  • DC/AC 0.68 — inverter oversized

A preliminary calculation; a design needs an engineer's check. Solispec engine 0.12.0.

Next

Other inverters for LONGi Hi-MO X10 LR7-54HVH-485M

Other panels for Deye SUN-5K-SG04LP1-EU