LONGi · Growatt

LONGi Hi-MO 7 LR7-72HGD-610M + Growatt MAX 100KTL3-X LV: how many panels per string

From 5 to 18 LONGi Hi-MO 7 LR7-72HGD-610M panels per string on an MPPT input of the Growatt MAX 100KTL3-X LV inverter — in any climatic region of Ukraine. Below: the window for each region, the input currents and example plants laid out by the Solispec engine.

Panels per string
5–18pcs
Input V_max
1,100V
MPPT window
180–1,000V
Panel I_sc
14.65A
MPPT input I_sc
40.0A
Panel V_mp in heat
37.8V

Ground frame designer

A ground plant with LONGi Hi-MO 7 LR7-72HGD-610M

The builder opens with this panel and the Growatt MAX 100KTL3-X LV inverter: Solispec lays out the strings itself.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

String by climatic region

T_min per ДСТУ-Н Б В.1.1-27:2010, табл. 1; open-circuit voltage at T_min: K_U = 1 + α·(T_min − 25)/100 = 1.15 (α -0.23 %/K, T_min -42 °C; Annex B).

RegionT_minPanel U_oc at T_min, VMin per stringMax per stringString U_oc at max, V (≤ 1,100)
Region I-40 °C60.285181,085.0
Region II-42 °C60.525181,089.4
Region IIIA-38 °C60.045181,080.7
Region IIIB-32 °C59.315181,067.7
Region IV-20 °C57.875191,099.5
Region V-27 °C58.715181,056.8

The minimum per string keeps the string voltage in heat (panel V_mp 37.8 V) above the MPPT window (180 V).

Input currents

Panel I_sc / MPPT input I_sc, A14.65 / 40.0
Panel I_mp / MPPT input I_mp, A13.76 / 32.0
Parallel strings per MPPT2
MPPT inputs10

No cautions about the currents.

Example plants

The Solispec engine laid out the strings for plants of several sizes with this inverter at the lowest T_min; only those that pass the checks with every panel placed are shown.

PlantPanelskW DCInvertersStringsDC/AC
≈ 5 kW95.4919 pan. × 1 — inv. 1, MPPT 10.05
≈ 10 kW1710.37117 pan. × 1 — inv. 1, MPPT 10.10
≈ 15 kW2515.2515 pan. × 2 — inv. 1, MPPT 1; 5 pan. × 2 — inv. 1, MPPT 2; 5 pan. × 1 — inv. 1, MPPT 30.15
  • DC/AC 0.05 — inverter oversized
  • U_OC MAX 1 029 В > 1000 В — звірте максимальну напругу системи панелей і апаратів (паспорт, 712.512.1.1)
  • DC/AC 0.10 — inverter oversized
  • DC/AC 0.15 — inverter oversized

A preliminary calculation; a design needs an engineer's check. Solispec engine 0.12.0.