LONGi · Deye

LONGi Hi-MO 6 LR5-54HTH-435M + Deye SUN-10K-G06P3-EU-BM2: how many panels per string

From 5 to 24 LONGi Hi-MO 6 LR5-54HTH-435M panels per string on an MPPT input of the Deye SUN-10K-G06P3-EU-BM2 inverter — in any climatic region of Ukraine. Below: the window for each region, the input currents and example plants laid out by the Solispec engine.

Panels per string
5–24pcs
Input V_max
1,100V
MPPT window
120–1,000V
Panel I_sc
14.22A
MPPT input I_sc
19.5A
Panel V_mp in heat
28.1V

Ground frame designer

A ground plant with LONGi Hi-MO 6 LR5-54HTH-435M

The builder opens with this panel and the Deye SUN-10K-G06P3-EU-BM2 inverter: Solispec lays out the strings itself.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

String by climatic region

T_min per ДСТУ-Н Б В.1.1-27:2010, табл. 1; open-circuit voltage at T_min: K_U = 1 + α·(T_min − 25)/100 = 1.15 (α -0.23 %/K, T_min -42 °C; Annex B).

RegionT_minPanel U_oc at T_min, VMin per stringMax per stringString U_oc at max, V (≤ 1,100)
Region I-40 °C45.215241,085.0
Region II-42 °C45.395241,089.4
Region IIIA-38 °C45.035241,080.7
Region IIIB-32 °C44.495241,067.7
Region IV-20 °C43.405251,085.0
Region V-27 °C44.035241,056.8

The minimum per string keeps the string voltage in heat (panel V_mp 28.1 V) above the MPPT window (120 V).

Input currents

Panel I_sc / MPPT input I_sc, A14.22 / 19.5
Panel I_mp / MPPT input I_mp, A13.17 / 13.0
Parallel strings per MPPT1
MPPT inputs2
  • Power clippingThe panel's working current (13.17 A) is above the input's working current (13.0 A): on clear days the inverter clips part of the power.

Example plants

The Solispec engine laid out the strings for plants of several sizes with this inverter at the lowest T_min; only those that pass the checks with every panel placed are shown.

PlantPanelskW DCInvertersStringsDC/AC
≈ 5 kW125.22112 pan. × 1 — inv. 1, MPPT 10.52
≈ 10 kW2310.01123 pan. × 1 — inv. 1, MPPT 11.00
≈ 15 kW3515.2329 pan. × 1 — inv. 1, MPPT 1; 9 pan. × 1 — inv. 1, MPPT 2; 9 pan. × 1 — inv. 2, MPPT 1; 8 pan. × 1 — inv. 2, MPPT 20.76
  • current 13.2 A > 13 A — the inverter will clip (clipping)
  • DC/AC 0.52 — inverter oversized
  • U_OC MAX 1 044 В > 1000 В — звірте максимальну напругу системи панелей і апаратів (паспорт, 712.512.1.1)

A preliminary calculation; a design needs an engineer's check. Solispec engine 0.12.0.