LONGi · Deye

LONGi Hi-MO 5 LR5-72HBD-545M + Deye SUN-10K-SG02LP1-EU-AM3: how many panels per string

From 5 to 8 LONGi Hi-MO 5 LR5-72HBD-545M panels per string on an MPPT input of the Deye SUN-10K-SG02LP1-EU-AM3 inverter — in any climatic region of Ukraine. Below: the window for each region, the input currents and example plants laid out by the Solispec engine.

Panels per string
5–8pcs
Input V_max
500V
MPPT window
150–425V
Panel I_sc
13.92A
MPPT input I_sc
44.0A
Panel V_mp in heat
35.6V

Ground frame designer

A ground plant with LONGi Hi-MO 5 LR5-72HBD-545M

The builder opens with this panel and the Deye SUN-10K-SG02LP1-EU-AM3 inverter: Solispec lays out the strings itself.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

String by climatic region

T_min per ДСТУ-Н Б В.1.1-27:2010, табл. 1; open-circuit voltage at T_min: K_U = 1 + α·(T_min − 25)/100 = 1.18 (α -0.265 %/K, T_min -42 °C; Annex B).

RegionT_minPanel U_oc at T_min, VMin per stringMax per stringString U_oc at max, V (≤ 500)
Region I-40 °C58.2058465.6
Region II-42 °C58.4758467.7
Region IIIA-38 °C57.9458463.5
Region IIIB-32 °C57.1558457.2
Region IV-20 °C55.5758444.6
Region V-27 °C56.4958451.9

The minimum per string keeps the string voltage in heat (panel V_mp 35.6 V) above the MPPT window (150 V).

Input currents

Panel I_sc / MPPT input I_sc, A13.92 / 44.0
Panel I_mp / MPPT input I_mp, A13.04 / 26.0
Parallel strings per MPPT1
MPPT inputs3

No cautions about the currents.

Example plants

The Solispec engine laid out the strings for plants of several sizes with this inverter at the lowest T_min; only those that pass the checks with every panel placed are shown.

PlantPanelskW DCInvertersStringsDC/AC
≈ 5 kW105.4515 pan. × 1 — inv. 1, MPPT 1; 5 pan. × 1 — inv. 1, MPPT 20.55
≈ 10 kW1910.3617 pan. × 1 — inv. 1, MPPT 1; 7 pan. × 1 — inv. 1, MPPT 2; 5 pan. × 1 — inv. 1, MPPT 31.04
≈ 15 kW2815.2627 pan. × 1 — inv. 1, MPPT 1; 7 pan. × 1 — inv. 1, MPPT 2; 7 pan. × 1 — inv. 2, MPPT 1; 7 pan. × 1 — inv. 2, MPPT 20.76
  • DC/AC 0.55 — inverter oversized

A preliminary calculation; a design needs an engineer's check. Solispec engine 0.12.0.

Next

Other inverters for LONGi Hi-MO 5 LR5-72HBD-545M

Other panels for Deye SUN-10K-SG02LP1-EU-AM3