Jinko · Solis

Jinko Tiger Neo JKM620N-66HL4M-V + Solis S5-GR3P20K: how many panels per string

From 5 to 19 Jinko Tiger Neo JKM620N-66HL4M-V panels per string on an MPPT input of the Solis S5-GR3P20K inverter — in any climatic region of Ukraine. Below: the window for each region, the input currents and example plants laid out by the Solispec engine.

Panels per string
5–19pcs
Input V_max
1,100V
MPPT window
160–1,000V
Panel I_sc
16.15A
MPPT input I_sc
40.0A
Panel V_mp in heat
34.8V

Ground frame designer

A ground plant with Jinko Tiger Neo JKM620N-66HL4M-V

The builder opens with this panel and the Solis S5-GR3P20K inverter: Solispec lays out the strings itself.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

String by climatic region

T_min per ДСТУ-Н Б В.1.1-27:2010, табл. 1; open-circuit voltage at T_min: K_U = 1 + α·(T_min − 25)/100 = 1.17 (α -0.25 %/K, T_min -42 °C; Annex B).

RegionT_minPanel U_oc at T_min, VMin per stringMax per stringString U_oc at max, V (≤ 1,100)
Region I-40 °C56.905191,081.2
Region II-42 °C57.155191,085.8
Region IIIA-38 °C56.665191,076.5
Region IIIB-32 °C55.935191,062.6
Region IV-20 °C54.465201,089.1
Region V-27 °C55.315191,051.0

The minimum per string keeps the string voltage in heat (panel V_mp 34.8 V) above the MPPT window (160 V).

Input currents

Panel I_sc / MPPT input I_sc, A16.15 / 40.0
Panel I_mp / MPPT input I_mp, A15.16 / 32.0
Parallel strings per MPPT2
MPPT inputs2
  • I_SC MAX above the input currentUnder DSTU HD 60364-7-712 the design current I_SC MAX = 1.25·I_SC of the panel is above the inverter's input current. Check in the inverter's datasheet how its input is rated.

Example plants

The Solispec engine laid out the strings for plants of several sizes with this inverter at the lowest T_min; only those that pass the checks with every panel placed are shown.

PlantPanelskW DCInvertersStringsDC/AC
≈ 5 kW95.5819 pan. × 1 — inv. 1, MPPT 10.28
≈ 10 kW1710.54117 pan. × 1 — inv. 1, MPPT 10.53
≈ 15 kW2515.5025 pan. × 2 — inv. 1, MPPT 1; 5 pan. × 2 — inv. 1, MPPT 2; 5 pan. × 1 — inv. 2, MPPT 10.39
  • DC/AC 0.28 — inverter oversized
  • DC/AC 0.53 — inverter oversized
  • I_SC MAX = 1.25·I_SC = 40.4 A > 40 A input — check how the inverter datasheet rates the input (712.512.1.2)
  • DC/AC 0.62 — inverter oversized
  • DC/AC 0.15 — inverter oversized

A preliminary calculation; a design needs an engineer's check. Solispec engine 0.12.0.

Next

Other inverters for Jinko Tiger Neo JKM620N-66HL4M-V

Other panels for Solis S5-GR3P20K