Jinko · Solis
Jinko Tiger Neo JKM590N-72HL4-V + Solis S6-EH1P6K-L-PLUS: how many panels per string
From 3 to 8 Jinko Tiger Neo JKM590N-72HL4-V panels per string on an MPPT input of the Solis S6-EH1P6K-L-PLUS inverter — in any climatic region of Ukraine. Below: the window for each region, the input currents and example plants laid out by the Solispec engine.
- Panels per string
- 3–8pcs
- Input V_max
- 500V
- MPPT window
- 90–435V
- Panel I_sc
- 14.13A
- MPPT input I_sc
- 20.0A
- Panel V_mp in heat
- 37.2V
Ground frame designer
A ground plant with Jinko Tiger Neo JKM590N-72HL4-V
The builder opens with this panel and the Solis S6-EH1P6K-L-PLUS inverter: Solispec lays out the strings itself.
- No sign-up
- Snow and wind check
- Drawings and estimate
String by climatic region
T_min per ДСТУ-Н Б В.1.1-27:2010, табл. 1; open-circuit voltage at T_min: K_U = 1 + α·(T_min − 25)/100 = 1.17 (α -0.25 %/K, T_min -42 °C; Annex B).
| Region | T_min | Panel U_oc at T_min, V | Min per string | Max per string | String U_oc at max, V (≤ 500) |
|---|---|---|---|---|---|
| Region I | -40 °C | 61.18 | 3 | 8 | 489.5 |
| Region II | -42 °C | 61.45 | 3 | 8 | 491.6 |
| Region IIIA | -38 °C | 60.92 | 3 | 8 | 487.4 |
| Region IIIB | -32 °C | 60.13 | 3 | 8 | 481.0 |
| Region IV | -20 °C | 58.55 | 3 | 8 | 468.4 |
| Region V | -27 °C | 59.47 | 3 | 8 | 475.8 |
The minimum per string keeps the string voltage in heat (panel V_mp 37.2 V) above the MPPT window (90 V).
Input currents
| Panel I_sc / MPPT input I_sc, A | 14.13 / 20.0 |
|---|---|
| Panel I_mp / MPPT input I_mp, A | 13.50 / 16.0 |
| Parallel strings per MPPT | 1 |
| MPPT inputs | 2 |
No cautions about the currents.
Example plants
The Solispec engine laid out the strings for plants of several sizes with this inverter at the lowest T_min; only those that pass the checks with every panel placed are shown.
| Plant | Panels | kW DC | Inverters | Strings | DC/AC |
|---|---|---|---|---|---|
| ≈ 5 kW | 9 | 5.31 | 1 | 5 pan. × 1 — inv. 1, MPPT 1; 4 pan. × 1 — inv. 1, MPPT 2 | 0.89 |
| ≈ 10 kW | 18 | 10.62 | 2 | 6 pan. × 1 — inv. 1, MPPT 1; 6 pan. × 1 — inv. 1, MPPT 2; 6 pan. × 1 — inv. 2, MPPT 1 | 0.89 |
| ≈ 15 kW | 27 | 15.93 | 4 | 4 pan. × 1 — inv. 1, MPPT 1; 4 pan. × 1 — inv. 1, MPPT 2; 4 pan. × 1 — inv. 2, MPPT 1; 4 pan. × 1 — inv. 2, MPPT 2; 4 pan. × 1 — inv. 3, MPPT 1; 3 pan. × 1 — inv. 3, MPPT 2; 4 pan. × 1 — inv. 4, MPPT 1 | 0.66 |
- DC/AC 0.59 — inverter oversized
- DC/AC 0.69 — inverter oversized
- DC/AC 0.39 — inverter oversized
A preliminary calculation; a design needs an engineer's check. Solispec engine 0.12.0.