Jinko · Deye

Jinko Tiger Neo JKM590N-72HL4-BDV + Deye SUN-10K-G06P3-EU-BM2: how many panels per string

From 4 to 17 Jinko Tiger Neo JKM590N-72HL4-BDV panels per string on an MPPT input of the Deye SUN-10K-G06P3-EU-BM2 inverter — in any climatic region of Ukraine. Below: the window for each region, the input currents and example plants laid out by the Solispec engine.

Panels per string
4–17pcs
Input V_max
1,100V
MPPT window
120–1,000V
Panel I_sc
14.07A
MPPT input I_sc
19.5A
Panel V_mp in heat
37.6V

Ground frame designer

A ground plant with Jinko Tiger Neo JKM590N-72HL4-BDV

The builder opens with this panel and the Deye SUN-10K-G06P3-EU-BM2 inverter: Solispec lays out the strings itself.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

String by climatic region

T_min per ДСТУ-Н Б В.1.1-27:2010, табл. 1; open-circuit voltage at T_min: K_U = 1 + α·(T_min − 25)/100 = 1.17 (α -0.25 %/K, T_min -42 °C; Annex B).

RegionT_minPanel U_oc at T_min, VMin per stringMax per stringString U_oc at max, V (≤ 1,100)
Region I-40 °C61.504171,045.4
Region II-42 °C61.764171,049.9
Region IIIA-38 °C61.234171,040.9
Region IIIB-32 °C60.444181,087.9
Region IV-20 °C58.854181,059.3
Region V-27 °C59.784181,076.0

The minimum per string keeps the string voltage in heat (panel V_mp 37.6 V) above the MPPT window (120 V).

Input currents

Panel I_sc / MPPT input I_sc, A14.07 / 19.5
Panel I_mp / MPPT input I_mp, A13.36 / 13.0
Parallel strings per MPPT1
MPPT inputs2
  • Power clippingThe panel's working current (13.36 A) is above the input's working current (13.0 A): on clear days the inverter clips part of the power.

Example plants

The Solispec engine laid out the strings for plants of several sizes with this inverter at the lowest T_min; only those that pass the checks with every panel placed are shown.

PlantPanelskW DCInvertersStringsDC/AC
≈ 5 kW95.3119 pan. × 1 — inv. 1, MPPT 10.53
≈ 10 kW1710.03117 pan. × 1 — inv. 1, MPPT 11.00
≈ 15 kW2615.34213 pan. × 1 — inv. 1, MPPT 1; 13 pan. × 1 — inv. 2, MPPT 10.77
  • current 13.4 A > 13 A — the inverter will clip (clipping)
  • DC/AC 0.53 — inverter oversized
  • U_OC MAX 1 050 В > 1000 В — звірте максимальну напругу системи панелей і апаратів (паспорт, 712.512.1.1)

A preliminary calculation; a design needs an engineer's check. Solispec engine 0.12.0.