Jinko · Afore

Jinko Tiger Neo JKM485N-60HL4-V + Afore BNT010KTL: how many panels per string

From 5 to 21 Jinko Tiger Neo JKM485N-60HL4-V panels per string on an MPPT input of the Afore BNT010KTL inverter — in any climatic region of Ukraine. Below: the window for each region, the input currents and example plants laid out by the Solispec engine.

Panels per string
5–21pcs
Input V_max
1,100V
MPPT window
150–1,000V
Panel I_sc
13.93A
MPPT input I_sc
25.0A
Panel V_mp in heat
30.9V

Ground frame designer

A ground plant with Jinko Tiger Neo JKM485N-60HL4-V

The builder opens with this panel and the Afore BNT010KTL inverter: Solispec lays out the strings itself.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

String by climatic region

T_min per ДСТУ-Н Б В.1.1-27:2010, табл. 1; open-circuit voltage at T_min: K_U = 1 + α·(T_min − 25)/100 = 1.17 (α -0.25 %/K, T_min -42 °C; Annex B).

RegionT_minPanel U_oc at T_min, VMin per stringMax per stringString U_oc at max, V (≤ 1,100)
Region I-40 °C50.875211,068.3
Region II-42 °C51.095211,072.9
Region IIIA-38 °C50.655211,063.7
Region IIIB-32 °C50.005221,099.9
Region IV-20 °C48.685221,071.0
Region V-27 °C49.455221,087.9

The minimum per string keeps the string voltage in heat (panel V_mp 30.9 V) above the MPPT window (150 V).

Input currents

Panel I_sc / MPPT input I_sc, A13.93 / 25.0
Panel I_mp / MPPT input I_mp, A13.38 / 15.0
Parallel strings per MPPT1
MPPT inputs2

No cautions about the currents.

Example plants

The Solispec engine laid out the strings for plants of several sizes with this inverter at the lowest T_min; only those that pass the checks with every panel placed are shown.

PlantPanelskW DCInvertersStringsDC/AC
≈ 5 kW115.34111 pan. × 1 — inv. 1, MPPT 10.53
≈ 10 kW2110.19121 pan. × 1 — inv. 1, MPPT 11.02
≈ 15 kW3115.0428 pan. × 1 — inv. 1, MPPT 1; 8 pan. × 1 — inv. 1, MPPT 2; 8 pan. × 1 — inv. 2, MPPT 1; 7 pan. × 1 — inv. 2, MPPT 20.75
  • DC/AC 0.53 — inverter oversized
  • U_OC MAX 1 073 В > 1000 В — звірте максимальну напругу системи панелей і апаратів (паспорт, 712.512.1.1)

A preliminary calculation; a design needs an engineer's check. Solispec engine 0.12.0.

Next

Other inverters for Jinko Tiger Neo JKM485N-60HL4-V

Other panels for Afore BNT010KTL