Jinko · Growatt

Jinko Tiger Neo JKM440N-54HL4R-BDV + Growatt SPH 6000TL BL-UP: how many panels per string

From 5 to 12 Jinko Tiger Neo JKM440N-54HL4R-BDV panels per string on an MPPT input of the Growatt SPH 6000TL BL-UP inverter — in any climatic region of Ukraine. Below: the window for each region, the input currents and example plants laid out by the Solispec engine.

Panels per string
5–12pcs
Input V_max
550V
MPPT window
120–550V
Panel I_sc
14.35A
MPPT input I_sc
16.9A
Panel V_mp in heat
27.6V

Ground frame designer

A ground plant with Jinko Tiger Neo JKM440N-54HL4R-BDV

The builder opens with this panel and the Growatt SPH 6000TL BL-UP inverter: Solispec lays out the strings itself.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

String by climatic region

T_min per ДСТУ-Н Б В.1.1-27:2010, табл. 1; open-circuit voltage at T_min: K_U = 1 + α·(T_min − 25)/100 = 1.17 (α -0.25 %/K, T_min -42 °C; Annex B).

RegionT_minPanel U_oc at T_min, VMin per stringMax per stringString U_oc at max, V (≤ 550)
Region I-40 °C45.31512543.8
Region II-42 °C45.51512546.1
Region IIIA-38 °C45.12512541.4
Region IIIB-32 °C44.53512534.4
Region IV-20 °C43.37512520.4
Region V-27 °C44.05512528.6

The minimum per string keeps the string voltage in heat (panel V_mp 27.6 V) above the MPPT window (120 V).

Input currents

Panel I_sc / MPPT input I_sc, A14.35 / 16.9
Panel I_mp / MPPT input I_mp, A13.58 / 13.5
Parallel strings per MPPT1
MPPT inputs2
  • Power clippingThe panel's working current (13.58 A) is above the input's working current (13.5 A): on clear days the inverter clips part of the power.
  • I_SC MAX above the input currentUnder DSTU HD 60364-7-712 the design current I_SC MAX = 1.25·I_SC of the panel is above the inverter's input current. Check in the inverter's datasheet how its input is rated.

Example plants

The Solispec engine laid out the strings for plants of several sizes with this inverter at the lowest T_min; only those that pass the checks with every panel placed are shown.

PlantPanelskW DCInvertersStringsDC/AC
≈ 5 kW125.28112 pan. × 1 — inv. 1, MPPT 10.88
≈ 10 kW2310.1226 pan. × 1 — inv. 1, MPPT 1; 6 pan. × 1 — inv. 1, MPPT 2; 6 pan. × 1 — inv. 2, MPPT 1; 5 pan. × 1 — inv. 2, MPPT 20.84
≈ 15 kW3515.4037 pan. × 1 — inv. 1, MPPT 1; 7 pan. × 1 — inv. 1, MPPT 2; 7 pan. × 1 — inv. 2, MPPT 1; 7 pan. × 1 — inv. 2, MPPT 2; 7 pan. × 1 — inv. 3, MPPT 10.86
  • current 13.6 A > 13.5 A — the inverter will clip (clipping)
  • I_SC MAX = 1.25·I_SC = 17.9 A > 16.9 A input — check how the inverter datasheet rates the input (712.512.1.2)
  • DC/AC 0.51 — inverter oversized

A preliminary calculation; a design needs an engineer's check. Solispec engine 0.12.0.

Next

Other inverters for Jinko Tiger Neo JKM440N-54HL4R-BDV

Other panels for Growatt SPH 6000TL BL-UP