Jinko · Fronius
Jinko Tiger Neo 3.0 JKM720N-66HL5-BDV + Fronius Primo 8.2-1: how many panels per string
From 3 to 17 Jinko Tiger Neo 3.0 JKM720N-66HL5-BDV panels per string on an MPPT input of the Fronius Primo 8.2-1 inverter — in any climatic region of Ukraine. Below: the window for each region, the input currents and example plants laid out by the Solispec engine.
- Panels per string
- 3–17pcs
- Input V_max
- 1,000V
- MPPT window
- 80–800V
- Panel I_sc
- 18.67A
- MPPT input I_sc
- 36.0A
- Panel V_mp in heat
- 34.8V
Ground frame designer
A ground plant with Jinko Tiger Neo 3.0 JKM720N-66HL5-BDV
The builder opens with this panel and the Fronius Primo 8.2-1 inverter: Solispec lays out the strings itself.
- No sign-up
- Snow and wind check
- Drawings and estimate
String by climatic region
T_min per ДСТУ-Н Б В.1.1-27:2010, табл. 1; open-circuit voltage at T_min: K_U = 1 + α·(T_min − 25)/100 = 1.17 (α -0.25 %/K, T_min -42 °C; Annex B).
| Region | T_min | Panel U_oc at T_min, V | Min per string | Max per string | String U_oc at max, V (≤ 1,000) |
|---|---|---|---|---|---|
| Region I | -40 °C | 57.01 | 3 | 17 | 969.2 |
| Region II | -42 °C | 57.25 | 3 | 17 | 973.3 |
| Region IIIA | -38 °C | 56.76 | 3 | 17 | 965.0 |
| Region IIIB | -32 °C | 56.03 | 3 | 17 | 952.5 |
| Region IV | -20 °C | 54.56 | 3 | 18 | 982.0 |
| Region V | -27 °C | 55.42 | 3 | 18 | 997.5 |
The minimum per string keeps the string voltage in heat (panel V_mp 34.8 V) above the MPPT window (80 V).
Input currents
| Panel I_sc / MPPT input I_sc, A | 18.67 / 36.0 |
|---|---|
| Panel I_mp / MPPT input I_mp, A | 17.61 / 18.0 |
| Parallel strings per MPPT | 1 |
| MPPT inputs | 2 |
No cautions about the currents.
Example plants
The Solispec engine laid out the strings for plants of several sizes with this inverter at the lowest T_min; only those that pass the checks with every panel placed are shown.
| Plant | Panels | kW DC | Inverters | Strings | DC/AC |
|---|---|---|---|---|---|
| ≈ 5 kW | 7 | 5.04 | 1 | 7 pan. × 1 — inv. 1, MPPT 1 | 0.61 |
| ≈ 10 kW | 14 | 10.08 | 1 | 14 pan. × 1 — inv. 1, MPPT 1 | 1.23 |
| ≈ 15 kW | 21 | 15.12 | 2 | 7 pan. × 1 — inv. 1, MPPT 1; 7 pan. × 1 — inv. 1, MPPT 2; 7 pan. × 1 — inv. 2, MPPT 1 | 0.92 |
- DC/AC 0.61 — inverter oversized
A preliminary calculation; a design needs an engineer's check. Solispec engine 0.12.0.