DMEGC · Solis
DMEGC Infinity RT DM440M10RT-54HBB + Solis S5-GR3P5K: how many panels per string
From 6 to 23 DMEGC Infinity RT DM440M10RT-54HBB panels per string on an MPPT input of the Solis S5-GR3P5K inverter — in any climatic region of Ukraine. Below: the window for each region, the input currents and example plants laid out by the Solispec engine.
- Panels per string
- 6–23pcs
- Input V_max
- 1,100V
- MPPT window
- 160–1,000V
- Panel I_sc
- 13.90A
- MPPT input I_sc
- 20.0A
- Panel V_mp in heat
- 28.0V
Ground frame designer
A ground plant with DMEGC Infinity RT DM440M10RT-54HBB
The builder opens with this panel and the Solis S5-GR3P5K inverter: Solispec lays out the strings itself.
- No sign-up
- Snow and wind check
- Drawings and estimate
String by climatic region
T_min per ДСТУ-Н Б В.1.1-27:2010, табл. 1; open-circuit voltage at T_min: K_U = 1 + α·(T_min − 25)/100 = 1.17 (α -0.25 %/K, T_min -42 °C; Annex B).
| Region | T_min | Panel U_oc at T_min, V | Min per string | Max per string | String U_oc at max, V (≤ 1,100) |
|---|---|---|---|---|---|
| Region I | -40 °C | 45.80 | 6 | 24 | 1,099.3 |
| Region II | -42 °C | 46.00 | 6 | 23 | 1,058.0 |
| Region IIIA | -38 °C | 45.61 | 6 | 24 | 1,094.5 |
| Region IIIB | -32 °C | 45.01 | 6 | 24 | 1,080.4 |
| Region IV | -20 °C | 43.83 | 6 | 25 | 1,095.8 |
| Region V | -27 °C | 44.52 | 6 | 24 | 1,068.5 |
The minimum per string keeps the string voltage in heat (panel V_mp 28.0 V) above the MPPT window (160 V).
Input currents
| Panel I_sc / MPPT input I_sc, A | 13.90 / 20.0 |
|---|---|
| Panel I_mp / MPPT input I_mp, A | 13.40 / 16.0 |
| Parallel strings per MPPT | 1 |
| MPPT inputs | 2 |
No cautions about the currents.
Example plants
The Solispec engine laid out the strings for plants of several sizes with this inverter at the lowest T_min; only those that pass the checks with every panel placed are shown.
| Plant | Panels | kW DC | Inverters | Strings | DC/AC |
|---|---|---|---|---|---|
| ≈ 5 kW | 12 | 5.28 | 1 | 12 pan. × 1 — inv. 1, MPPT 1 | 1.06 |
| ≈ 10 kW | 24 | 10.56 | 2 | 12 pan. × 1 — inv. 1, MPPT 1; 12 pan. × 1 — inv. 2, MPPT 1 | 1.06 |
| ≈ 15 kW | 35 | 15.40 | 3 | 7 pan. × 1 — inv. 1, MPPT 1; 7 pan. × 1 — inv. 1, MPPT 2; 7 pan. × 1 — inv. 2, MPPT 1; 7 pan. × 1 — inv. 2, MPPT 2; 7 pan. × 1 — inv. 3, MPPT 1 | 1.03 |
- DC/AC 0.62 — inverter oversized
A preliminary calculation; a design needs an engineer's check. Solispec engine 0.12.0.