Astronergy · Solis

Astronergy ASTRO N8 CHSM66N(DG)/F-BH-720 + Solis S6-GC100K: how many panels per string

From 5 to 19 Astronergy ASTRO N8 CHSM66N(DG)/F-BH-720 panels per string on an MPPT input of the Solis S6-GC100K inverter — in any climatic region of Ukraine. Below: the window for each region, the input currents and example plants laid out by the Solispec engine.

Panels per string
5–19pcs
Input V_max
1,100V
MPPT window
160–1,000V
Panel I_sc
18.58A
MPPT input I_sc
50.0A
Panel V_mp in heat
34.8V

Ground frame designer

A ground plant with Astronergy ASTRO N8 CHSM66N(DG)/F-BH-720

The builder opens with this panel and the Solis S6-GC100K inverter: Solispec lays out the strings itself.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

String by climatic region

T_min per ДСТУ-Н Б В.1.1-27:2010, табл. 1; open-circuit voltage at T_min: K_U = 1 + α·(T_min − 25)/100 = 1.17 (α -0.25 %/K, T_min -42 °C; Annex B).

RegionT_minPanel U_oc at T_min, VMin per stringMax per stringString U_oc at max, V (≤ 1,100)
Region I-40 °C57.165191,086.0
Region II-42 °C57.415191,090.7
Region IIIA-38 °C56.915191,081.4
Region IIIB-32 °C56.185191,067.4
Region IV-20 °C54.705201,094.0
Region V-27 °C55.565191,055.7

The minimum per string keeps the string voltage in heat (panel V_mp 34.8 V) above the MPPT window (160 V).

Input currents

Panel I_sc / MPPT input I_sc, A18.58 / 50.0
Panel I_mp / MPPT input I_mp, A17.64 / 36.0
Parallel strings per MPPT2
MPPT inputs10

No cautions about the currents.

Example plants

The Solispec engine laid out the strings for plants of several sizes with this inverter at the lowest T_min; only those that pass the checks with every panel placed are shown.

PlantPanelskW DCInvertersStringsDC/AC
≈ 5 kW75.0417 pan. × 1 — inv. 1, MPPT 10.05
≈ 10 kW1410.08114 pan. × 1 — inv. 1, MPPT 10.10
≈ 15 kW2115.1217 pan. × 2 — inv. 1, MPPT 1; 7 pan. × 1 — inv. 1, MPPT 20.15
  • DC/AC 0.05 — inverter oversized
  • DC/AC 0.10 — inverter oversized
  • DC/AC 0.15 — inverter oversized

A preliminary calculation; a design needs an engineer's check. Solispec engine 0.12.0.