30 kWp ground-mount PV plant: structure and loads
The structure of a 30 kWp ground-mount PV plant in Berlin step by step: snow and wind, profile, concrete block weight under each support, row spacing. Every figure from the Solispec engine.
Ten tekst nie jest jeszcze przetłumaczony na Twój język — pokazujemy oryginał.
A 30 kWp ground-mount PV plant in this example is 48 panels on twelve rows of structure, four panels each. Below is the whole calculation in order: loads, profile, supports on concrete blocks, row spacing. Every figure comes from the same engine functions that stand behind the ground truss calculator, so you can repeat the calculation with your own data.
Inputs
- Panel: Tongwei TWMNH-66HD, 640 W, 2382 x 1134 mm. 48 panels make 30.72 kWp.
- Layout: 12 rows of 4 panels in portrait, tilt 34 degrees.
- Site: Berlin, snow load zone 2 and wind zone 2 by the national annexes, in the calculator s_k = 850 Pa and q_b = 390 Pa.
- Profile: perforated C 41 x 41 x 3 mm. Supports: cast concrete cubes of 400 mm, 150 kg each.
Loads
Snow and wind come from DIN EN 1991-1-3 and DIN EN 1991-1-4 with the national annexes, and the partial factor for variable actions is 1.5 to DIN EN 1990. Wind acts on the tilted panels with the pressure coefficient of EN 1991-1-4, and the resultant is off-centre. Both combinations are checked: snow leading and wind leading. How this is organised is in the article on the ground mount structure for solar panels.
Truss and profile
A row of 4 panels sits on 6 trusses 860 mm apart. The most loaded member is the rafter K1, used to 90 %, so there is margin. The rail, strut, base, rear post and node are loaded less. One row takes about 189 kg of steel, all twelve rows 2271 kg.
The calculator also notes the top overhang of the panel beyond the end of the truss: an item for the designer, not a profile error.
Supports: how much a block must weigh
Each truss stands on two supports, so a row has 12 and the plant 144. For each support the engine computes two figures:
- against uplift, 335 kg;
- against sliding by friction on the ground (0.35), 431 kg.
The larger one governs, 431 kg. A concrete cube weighs 150 kg, so the calculator uses three layers, 450 kg per support. For the plant that is 432 cubes and about 64800 kg of concrete. That is a lot of mass for an open field: screw foundations in place of blocks also pass the check, and their capacity is confirmed by a trial screw-in on site. Block weights for other zones and tilts are in the table on the calculator page.
Row spacing
By the method of the tilt and row spacing calculator for the latitude of Berlin, the row pitch is 8.91 m, the clear gap between rows 6.9 m and the ground coverage ratio 0.27. The horizontal depth of one row is 1.97 m. A shorter pitch shades the rows in winter, a longer one enlarges the plot. Work out your own variant in the tilt and spacing calculator.
In short
- 48 panels of 640 W, 30.72 kWp, 12 rows of 4 panels.
- Berlin: s_k = 850 Pa, q_b = 390 Pa.
- Truss spacing 860 mm, highest utilisation the rafter, 90 %.
- Support: 431 kg, three 150 kg cubes per support, 432 cubes for the plant.
- Row pitch 8.91 m.
Other types of structure and a comparison of piles and blocks are on the ground mounting page. For another site change the values in the snow and wind calculator, and the full set of drawings and specifications comes from the designer.
The calculation is preliminary. A qualified engineer must check it before installation.
FAQ
How much concrete does a 30 kWp ground-mount plant need?
In the example above, 432 cubes of 150 kg, about 64800 kg: three per support across 144 supports. The weight depends on tilt and wind zone, so recalculate your own site in the calculator.
Piles or concrete blocks?
Both pass the check in the example. Piles need no weight, but their capacity is confirmed on site. Blocks need the weight that the support calculation gives.
What row spacing should I use in Berlin?
By the calculator method, 8.91 m for a 34 degree tilt. The method and formulas are on the tilt and row spacing calculator page.